2020
DOI: 10.1002/mp.14243
|View full text |Cite
|
Sign up to set email alerts
|

Technical Note: Rapid multiexponential curve fitting algorithm for voxel‐based targeted radionuclide dosimetry

Abstract: Background: Dosimetry in nuclear medicine often relies on estimating pharmacokinetics based on sparse temporal data. As analysis methods move toward image-based three-dimensional computation, it becomes important to interpolate and extrapolate these data without requiring manual intervention; that is, in a manner that is highly efficient and reproducible. Iterative least-squares solvers are poorly suited to this task because of the computational overhead and potential to optimize to local minima without applyi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 25 publications
0
5
0
Order By: Relevance
“…This step leads to a Time Dose-Rate Curve (TDRC) for all injections, similar to the conventional Time-Activity Curve (TAC) except that it is determined with dose rate and not the activity, thus already integrating the cross-dose. In order to compute the total absorbed dose corresponding to the time integral of those curves, the analytical method proposed by Jackson et al [ 35 , 36 ] based on tri-exponential function was used by replacing activity ( A ) with dose rate ( ), as shown in Eq. ( 1 ).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…This step leads to a Time Dose-Rate Curve (TDRC) for all injections, similar to the conventional Time-Activity Curve (TAC) except that it is determined with dose rate and not the activity, thus already integrating the cross-dose. In order to compute the total absorbed dose corresponding to the time integral of those curves, the analytical method proposed by Jackson et al [ 35 , 36 ] based on tri-exponential function was used by replacing activity ( A ) with dose rate ( ), as shown in Eq. ( 1 ).…”
Section: Methodsmentioning
confidence: 99%
“…1 . Tri-exponential parameters were computed with the same algorithm described in [ 35 ]; therefore, all were decay-corrected before fitting TDRC, and the correction was reversed during integration. ODR was assumed to be equal to zero just before the treatment and 600H after the injection.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…For SPECT/CT analysis, representative ellipsoid or spheric volumes of interest for organs and voxelwise volumes of interest covering the entire tumors were drawn on the basis of the CT component of the SPECT/CT. For estimation of self-absorbed dose (or specific absorbed dose, expressed in Gy/MBq) in organs and tumors, time-activity curves of single animals were fitted according to the method of Jackson et al using the scripted implementation (42). This involved using a model consisting of a triexponential function fitted to the latest 3 acquisitions.…”
Section: Implantation Of Subcutaneous Tumorsmentioning
confidence: 99%
“…Similarly, Huizing et al compared the same software packages using both mono-exponential and bi-exponential fittings [30]. Jackson et al, proposed a tri-exponential algorithm for absorbed dose calculation in patients undergoing PRRT with 177 Lu-DOTATATE [31]. From those studies, it is evident that further research on the fitting methods is deemed necessary.…”
Section: Introductionmentioning
confidence: 99%