Purpose
To evaluate pix2pix and CycleGAN and to assess the effects of multiple combination strategies on accuracy for patch‐based synthetic computed tomography (sCT) generation for magnetic resonance (MR)‐only treatment planning in head and neck (HN) cancer patients.
Materials and methods
Twenty‐three deformably registered pairs of CT and mDixon FFE MR datasets from HN cancer patients treated at our institution were retrospectively analyzed to evaluate patch‐based sCT accuracy via the pix2pix and CycleGAN models. To test effects of overlapping sCT patches on estimations, we (a) trained the models for three orthogonal views to observe the effects of spatial context, (b) we increased effective set size by using per‐epoch data augmentation, and (c) we evaluated the performance of three different approaches for combining overlapping Hounsfield unit (HU) estimations for varied patch overlap parameters. Twelve of twenty‐three cases corresponded to a curated dataset previously used for atlas‐based sCT generation and were used for training with leave‐two‐out cross‐validation. Eight cases were used for independent testing and included previously unseen image features such as fused vertebrae, a small protruding bone, and tumors large enough to deform normal body contours. We analyzed the impact of MR image preprocessing including histogram standardization and intensity clipping on sCT generation accuracy. Effects of mDixon contrast (in‐phase vs water) differences were tested with three additional cases. The sCT generation accuracy was evaluated using mean absolute error (MAE) and mean error (ME) in HU between the plan CT and sCT images. Dosimetric accuracy was evaluated for all clinically relevant structures in the independent testing set and digitally reconstructed radiographs (DRRs) were evaluated with respect to the plan CT images.
Results
The cross‐validated MAEs for the whole‐HN region using pix2pix and CycleGAN were 66.9 ± 7.3 vs 82.3 ± 6.4 HU, respectively. On the independent testing set with additional artifacts and previously unseen image features, whole‐HN region MAEs were 94.0 ± 10.6 and 102.9 ± 14.7 HU for pix2pix and CycleGAN, respectively. For patients with different tissue contrast (water mDixon MR images), the MAEs increased to 122.1 ± 6.3 and 132.8 ± 5.5 HU for pix2pix and CycleGAN, respectively. Our results suggest that combining overlapping sCT estimations at each voxel reduced both MAE and ME compared to single‐view non‐overlapping patch results. Absolute percent mean/max dose errors were 2% or less for the PTV and all clinically relevant structures in our independent testing set, including structures with image artifacts. Quantitative DRR comparison between planning CTs and sCTs showed agreement of bony region positions to <1 mm.
Conclusions
The dosimetric and MAE based accuracy, along with the similarity between DRRs from sCTs, indicate that pix2pix and CycleGAN are promising methods for MR‐only treatment planning for HN cancer. Our methods investigated for overlapping patch‐based HU estimations also ...