Techniques and Results—Penumbra Aspiration Catheter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2013
2013
2016
2016

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 21 publications
0
5
0
Order By: Relevance
“…The 4 Fr catheter used in these experiments is at the lower range of sizes used for intracranial suction thrombectomy (internal diameter 0.89–1.63 mm) in clinical practice,20 23 24 but appropriate for the size of the experimental vessel. The diameter of the catheter has no bearing on the conclusions of this work as the results are qualitative rather than quantitative.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The 4 Fr catheter used in these experiments is at the lower range of sizes used for intracranial suction thrombectomy (internal diameter 0.89–1.63 mm) in clinical practice,20 23 24 but appropriate for the size of the experimental vessel. The diameter of the catheter has no bearing on the conclusions of this work as the results are qualitative rather than quantitative.…”
Section: Discussionmentioning
confidence: 99%
“…The size of the catheter was chosen to match the size of the target vessel (2.4 mm) using recommendations for catheter size for currently used catheters in vivo 20 21…”
Section: Methodsmentioning
confidence: 99%
“…A currently FDA-approved proximal mechanical retriever for the treatment of ischemic stroke is Penumbra (Penumbra Inc., Alameda, CA). Penumbra uses a separator at the tip of the instrument combined with aspiration to disrupt and remove the occlusive clot using an axial push force [18][19][20][21]. Geunther et al [22] propose a different designed proximal mechanical retriever in combination with a distal balloon and [23,24] a proximal expandable cylindrical tube cutter in combination with a distal balloon for axial clot resection and removal, respectively (Fig.…”
Section: A) Low-speed Impact Forcementioning
confidence: 99%
“…While several recent studies have shown that both the Penumbra aspiration system and FST are safe and efficacious in the treatment of ischemic stroke, they have also alluded to the fact that FST represents a quicker and more flexible treatment option 1 3 4. Because of its minimalistic design, FST provides advantages in preparation time and time to revascularization.…”
Section: Introductionmentioning
confidence: 99%
“…Because of its minimalistic design, FST provides advantages in preparation time and time to revascularization. Additionally, if FST fails, it can be quickly and easily converted to the Penumbra system 1 3…”
Section: Introductionmentioning
confidence: 99%