2021
DOI: 10.1002/chem.202102474
|View full text |Cite
|
Sign up to set email alerts
|

Temperature‐Controlled Electrospray Ionization: Recent Progress and Applications

Abstract: Native electrospray ionization (ESI) and nanoelectrospray ionization (nESI) allow researchers to analyze intact biomolecules and their complexes by mass spectrometry (MS). The data acquired using these soft ionization techniques provide a snapshot of a given biomolecules structure in solution. Over the last thirty years, several nESI and ESI sources capable of controlling spray solution temperature have been developed. These sources can be used to elucidate the thermodynamics of a given analyte, as well as pro… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 99 publications
1
5
0
Order By: Relevance
“…This temperature-induced effect for System 1 is consistent with a known phenomenon in mass spectrometry, where excessive source temperatures promote fragmentation and denaturation. 43,44 When we applied this temperature ramp to System 2, it became evident that detection of the n = 4 ion was virtually non-existent, even at low source temperatures. This very low abundance of highcoordinate ions suggests that other aspects of the instrument design, rather than in-source thermal ion fragmentation, are the cause of softness limitations in System 2.…”
Section: Impact Of Source Temperatures On Ion Fragmentation Profilesmentioning
confidence: 99%

How soft is your ESI-MS anyway?

Chagunda,
Williams,
Fisher
et al. 2024
Preprint
“…This temperature-induced effect for System 1 is consistent with a known phenomenon in mass spectrometry, where excessive source temperatures promote fragmentation and denaturation. 43,44 When we applied this temperature ramp to System 2, it became evident that detection of the n = 4 ion was virtually non-existent, even at low source temperatures. This very low abundance of highcoordinate ions suggests that other aspects of the instrument design, rather than in-source thermal ion fragmentation, are the cause of softness limitations in System 2.…”
Section: Impact Of Source Temperatures On Ion Fragmentation Profilesmentioning
confidence: 99%

How soft is your ESI-MS anyway?

Chagunda,
Williams,
Fisher
et al. 2024
Preprint
“…In agreement with principles of enzyme mechanisms, previous MS studies have highlighted the importance of controlling temperature. 37,38 This is of particular importance for measuring PLA 2 activity, as temperature can affect both enzyme stability and lipid membrane conformation/integrity. The effect of temperature on PDx enzymatic activity was investigated under the standard assay conditions (PDx (6 nM); DOPC liposomes (80 μM), in 100 mM NH 4 OAc, 2 mM in Ca(OAc) 2 ).…”
Section: Effect Of Lpc Concentration On the Ionization Of Dopcmentioning
confidence: 99%
“…Multiple designs exist for TC-nESI-MS sources, each of which has been used to investigate a range of biomolecules. 30 However, this technique has yet to be employed for proteomics analysis.…”
Section: ■ Introductionmentioning
confidence: 99%
“…The resulting temperature-induced changes in a biomolecule can then be detected by MS. Multiple designs exist for TC-nESI-MS sources, each of which has been used to investigate a range of biomolecules . However, this technique has yet to be employed for proteomics analysis.…”
Section: Introductionmentioning
confidence: 99%