2010
DOI: 10.1117/1.3290820
|View full text |Cite
|
Sign up to set email alerts
|

Temperature-dependent optical properties of Intralipid® measured with frequency-domain photon-migration spectroscopy

Abstract: Abstract. We present the temperature dependence of absorption and reduced scattering coefficients of 1.8% Intralipid measured by frequency-domain photon-migration spectroscopy between 710 and 850 nm. These measurements were made in the physiologically relevant 30 to 40°C temperature range. The temperature coefficients for absorption were consistent during heating and cooling and follow closely other reported results. The change in absorption coefficient at 740 nm suggests that a minimum temperature change of 4… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
24
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(26 citation statements)
references
References 27 publications
2
24
0
Order By: Relevance
“…Right before measurements of both diffusivity and particle size, these samples were remixed to ensure sample homogeneity. The measured μ 0 s from all these samples was between 9.0 and 11 cm −1 , confirming the previous reports 25,31 on the diffusivity of Intralipid-water samples. Figure 8(a) is an example of a lipid droplet size distribution histogram measured by the DLS method.…”
Section: Discussionsupporting
confidence: 90%
See 3 more Smart Citations
“…Right before measurements of both diffusivity and particle size, these samples were remixed to ensure sample homogeneity. The measured μ 0 s from all these samples was between 9.0 and 11 cm −1 , confirming the previous reports 25,31 on the diffusivity of Intralipid-water samples. Figure 8(a) is an example of a lipid droplet size distribution histogram measured by the DLS method.…”
Section: Discussionsupporting
confidence: 90%
“…Further investigation can clarify this matter, but is outside the scope of this paper. To fabricate Intralipid-gelatin-water phantoms having optical diffusivity that is consistent with that of Intralipid-water counterparts, 25,31 we found it is crucial to maintain the mixing temperature below 37°C and use mixing times not exceeding 2 h. We recommend our modified protocol for making Intralipid-gelatin-water phantoms for future optical experiments.…”
Section: Resultsmentioning
confidence: 94%
See 2 more Smart Citations
“…For turbid liquid dispersions, Photon Density Wave (PDW) spectroscopy [1][2][3] provides this fundamental benefit. Recently, this technology was further developed to demonstrate its applicability to the monitoring of chemical or physical processes within liquid turbid systems [4][5][6][7].…”
Section: Introductionmentioning
confidence: 99%