2021
DOI: 10.1038/s41598-021-02998-2
|View full text |Cite
|
Sign up to set email alerts
|

Temperature responsive chromatography for therapeutic drug monitoring with an aqueous mobile phase

Abstract: Therapeutic drug monitoring is a key technology for effective pharmacological treatment. In the present study, a temperature-responsive chromatography column was developed for safe and simple therapeutic drug monitoring without the use of organic solvents. Poly(N-isopropylacrylamide) (PNIPAAm) hydrogel-modified silica beads were prepared via a condensation reaction and radical polymerization. The temperature-dependent elution behavior of the drugs was observed using a PNIPAAm-modified silica-bead packed column… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 58 publications
0
10
0
Order By: Relevance
“…These results indicate that the three types of copolymers were successfully modified on silica beads through radical polymerization. The absorbance of aminopropyl silica beads increased with increasing wavenumber, which led to a small difference in the peak height between the copolymer-modified silica beads and aminopropyl silica beads compared with that of the previously reported FT-IR analysis of the polymer-modified beads 41 .
Figure 2 ( A ) FT-IR spectra and ( B ) SEM images of the prepared beads.
…”
Section: Resultsmentioning
confidence: 53%
See 2 more Smart Citations
“…These results indicate that the three types of copolymers were successfully modified on silica beads through radical polymerization. The absorbance of aminopropyl silica beads increased with increasing wavenumber, which led to a small difference in the peak height between the copolymer-modified silica beads and aminopropyl silica beads compared with that of the previously reported FT-IR analysis of the polymer-modified beads 41 .
Figure 2 ( A ) FT-IR spectra and ( B ) SEM images of the prepared beads.
…”
Section: Resultsmentioning
confidence: 53%
“…In a previous study, a temperature-responsive chromatography column was investigated for applicability in TDM 41 , 42 . Drug concentrations in a sample can be analyzed using temperature-responsive chromatography with all-aqueous mobile phases 41 , 42 .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…A mixed-mode column was prepared by combining PNIPAAm and PAPTAC beads and packing them into an empty column (4.6 inner diameter × 50 mm length) 44 . Solely PNIPAAm-modified beads packed column and PNIPAAm-modified beads (0.8 g) were suspended in 20 mL of a 1:1:1 mixed solvent of water:methanol:2-propanol.…”
Section: Methodsmentioning
confidence: 99%
“…In the case of the PNIPAAm:PAPTAC = 20:1 column, PNIPAAm-modified beads (0.764 g) and PAPTAC-modified beads (0.0382 g) were suspended in the mixed solvent, while in that of PNIPAAm:PAPTAC = 10:1 column, PNIPAAm-modified beads (0.727 g) and PAPTAC-modified beads (0.0727 g) were suspended in the mixed solvent. The bead suspension was poured into the reservoir of the column packer that was connected to an empty column 44 . Beads were packed to enable a continuous flow of a mixed solvent with a continuous pressure of 350 kg/cm 2 for 1 h 43 .…”
Section: Methodsmentioning
confidence: 99%