11th International Symposium on High-Voltage Engineering (ISH 99) 1999
DOI: 10.1049/cp:19990753
|View full text |Cite
|
Sign up to set email alerts
|

Temporal breakdown development of a covered rod/plane air-gap arrangement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
3
0
2

Year Published

2008
2008
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 0 publications
0
3
0
2
Order By: Relevance
“…These effects may result from the differences in the characteristics between surface and air discharges and from surface charge accumulation as influenced by the temporal variation of the electric field. Charge deposition by surface corona streamers on insulating surfaces has been shown to occur under lightning impulses [6][7], [13][14]. Surface charge accumulation due to coronas might also affect the discharge path at breakdown [14][15][16][17]; in the present dielectric covered rod/plane gaps there were cases where breakdown occurred solely in free air.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…These effects may result from the differences in the characteristics between surface and air discharges and from surface charge accumulation as influenced by the temporal variation of the electric field. Charge deposition by surface corona streamers on insulating surfaces has been shown to occur under lightning impulses [6][7], [13][14]. Surface charge accumulation due to coronas might also affect the discharge path at breakdown [14][15][16][17]; in the present dielectric covered rod/plane gaps there were cases where breakdown occurred solely in free air.…”
Section: Discussionmentioning
confidence: 99%
“…In a covered plane-parallel electrode system under dc and lightning impulses the increased dielectric strength of the gap was attributed to charge formation at the electrode surfaces as well as in the air gap [4]. An increased dielectric strength due to dielectric covers has also been observed in rod-plane configurations [5][6][7][8][9][10][11], where the apparent non-uniformity of the electric field approximates better the enhanced localized field values commonly found in insulation systems. However, this behavior depends on the electric field distribution in the gap as modified by space and surface charges associated with prebreakdown phenomena.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Σε άλλη εργασία τους, οι Ming et al [15] σε δοκίµιο ίδιο µε προηγουµένως, µε δεδοµένο µήκος διακένου και επικάλυψης, λαµβάνουν διαδοχικές φωτογραφίες µε υψηλό ρυθµό λήψεων της εξέλιξης των εκκενώσεων υπό θετικές και αρνητικές εξωτερικές κρουστικές τάσεις. ∆ιαπιστώνουν ότι στην περίπτωση των θετικών κρουστικών τάσεων o σπινθήρας καλύπτει πρώτα το µήκος της επικάλυψης και µετά το υπόλοιπο διάκενο, ενώ στην περίπτωση των αρνητικών κρουστικών τάσεων συµβαίνει το αντίθετο.…”
Section: εισαγωγηunclassified
“…Αυτή η συσσώρευση φορτίων, αυξάνοντας τις τιµές του ηλεκτρικού πεδίου εντός της επικάλυψης και µειώνοντας αυτές στον αέρα, επηρεάζει την ανάπτυξη των νηµατίων στον αέρα και των εκκενώσεων κατά µήκος της διηλεκτρική επιφάνειας. Οι ίδιοι δείχνουν ότι υπό θετικές τάσεις ο σπινθήρας καλύπτει πρώτα την επιφάνεια του διηλεκτρικού και ύστερα το υπόλοιπο διάκενο αέρα ενώ το αντίθετο συµβαίνει υπό αρνητικές τάσεις [15]. Επίσης γίνεται η εκτίµηση ότι ο χρόνος διάσπασης είναι µεγαλύτερος υπό αρνητικές τάσεις ως αποτέλεσµα της χαµηλότερης ταχύτητας προόδου των αρνητικών νηµατίων.…”
Section: εξέλιξη της εκκένωσηςunclassified