2022
DOI: 10.1002/ccd.30178
|View full text |Cite
|
Sign up to set email alerts
|

Temporal changes and clinical significance of peridevice leak following left atrial appendage occlusion with Amplatzer devices

Abstract: Background: The natural history of peridevice leak (PDL) following left atrial appendage occlusion (LAAO) is unknown. This study sought to investigate changes of PDL from 2 until 12 months after LAAO, using cardiac computed tomography (CT), and to assess the potential association between persistent PDL and clinical outcomes Methods: Single-center observational study of Amplatzer LAAO implants between 2010 and 2017 (n = 206). Patients with 2 and 12 months cardiac CT were included in the study (n = 153). Images … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
19
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 18 publications
(20 citation statements)
references
References 31 publications
0
19
0
1
Order By: Relevance
“…The cut-off for clinically acceptable PDL size has been arbitrarily defined and the significance remains debatable (5,19,23). The natural history of PDL is unclear, but smaller PDL (< 3 mm) adjacent to Watchman 2.5 devices may reduce in size over time (24), while a cardiac CT and TEE study revealed no significant PDL size reduction over time with Amplatzer devices (25). Nevertheless, contrast patency at 1 year is common and likely represents incomplete endothelialization with contrast passing through the device membrane.…”
Section: Clinical Significance Of Pdlmentioning
confidence: 99%
“…The cut-off for clinically acceptable PDL size has been arbitrarily defined and the significance remains debatable (5,19,23). The natural history of PDL is unclear, but smaller PDL (< 3 mm) adjacent to Watchman 2.5 devices may reduce in size over time (24), while a cardiac CT and TEE study revealed no significant PDL size reduction over time with Amplatzer devices (25). Nevertheless, contrast patency at 1 year is common and likely represents incomplete endothelialization with contrast passing through the device membrane.…”
Section: Clinical Significance Of Pdlmentioning
confidence: 99%
“…1). After reviewing and assessing the inclusion and exclusion criteria, only thirteen articles [1628] met the criteria and were included in the meta-analysis. These articles, which included a total of 54,405 patients, were all observational trials.…”
Section: Resultsmentioning
confidence: 99%
“…In the PROTECT AF trial, any PDL was detected in 40.9% of patients during follow-up TOE imaging at 45 days but decreased to 32.1% at 1 year. Large PDL (>3 mm in diameter) were present in 13.3% patients at 45 days and in 11.8% at 1 year 90 . In a large nationwide cohort of >50,000 patients enrolled in the NCDR-LAAO Registry, small leaks (1-5 mm) were present in ~25% of patients, while large (>5 mm) leaks were rare (<1%) 92 (Figure 19).…”
Section: Incidencementioning
confidence: 94%
“…The pivotal PROTECT AF and PREVAIL follow-up included 45-day, 6-and 12-month imaging which has been extrapolated to clinical practice 89 . Changes in post-procedural anticoagulation regimen 71,88 and studies demonstrating persistent PDL or signs of incomplete device endothelialisation at 1 year raise questions about the optimal timing of follow-up 89,90 . Early imaging follow-up is, however, generally recommended, while longer-term imaging follow-up of patients with DRT or HAT and those with large PDL may warrant sequential follow-up imaging.…”
Section: Post-procedural Imagingmentioning
confidence: 99%