1988
DOI: 10.1016/0142-9612(88)90027-0
|View full text |Cite
|
Sign up to set email alerts
|

Tensile properties of suture materials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
59
0

Year Published

1991
1991
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 67 publications
(67 citation statements)
references
References 6 publications
4
59
0
Order By: Relevance
“…Suturing has been blamed for reducing the durability of cardiac valve leaflets, provoked by both the shearing stress exerted on the biomaterial by the threads 26 and their interaction with the tissue, producing areas of lower resistance, [27][28][29] despite the proven high resistance to rupture of the biomaterial. 30,31 When the results in sutured samples of calf pericardium were compared, the mean resistance to tearing was significantly greater in those sewn with the telescoping suture placed perpendicularly to the load, regardless of whether they had been cut longitudinally or transversely (range of significance: p ϭ .000 to p ϭ .004). These findings are clearly shown in Tables I and II and Figure 7.…”
Section: -25mentioning
confidence: 96%
“…Suturing has been blamed for reducing the durability of cardiac valve leaflets, provoked by both the shearing stress exerted on the biomaterial by the threads 26 and their interaction with the tissue, producing areas of lower resistance, [27][28][29] despite the proven high resistance to rupture of the biomaterial. 30,31 When the results in sutured samples of calf pericardium were compared, the mean resistance to tearing was significantly greater in those sewn with the telescoping suture placed perpendicularly to the load, regardless of whether they had been cut longitudinally or transversely (range of significance: p ϭ .000 to p ϭ .004). These findings are clearly shown in Tables I and II and Figure 7.…”
Section: -25mentioning
confidence: 96%
“…Fraunhofer et al [110] Not Greenwald et al [108] Sutures were wound around non-rotating spools (4.75 mm diameter)…”
Section: Heat Shrinkagementioning
confidence: 99%
“…[ 5,108,109 ] Suture fi laments are commonly tested, recording the applied loads and the cross-head movement of the test setup. [ 8,109,110 ] The investigation of knotted loops or straight fi laments possessing a centered knot (single overhand throw simple knot) are typical modifi cations of the test procedure that can be found in the literature. [ 5,44,109,118 ] Fraunhofer et al [ 111 ] and Fu et al [ 112 ] conducted dynamic mechanical tensile strength testing at various temperatures and then used a time-temperature superposition principle to determine both short-and longterm properties of sutures.…”
Section: Mechanical Properties For Polymeric Suturesmentioning
confidence: 99%
“…This is in contrast to other cardiovascular sutures, which have constant, high resistance to stretch. 2,3 The biphasic nature of the elongation of elastomeric polybutester sutures was intended to offer better compliance with the blood vessel in vascular anastomoses and allow for expansion and contraction in the diameter, which can be up to 15%, 4 of the aorta and coronary and peripheral arteries caused by the pulsatile nature of blood flow close to the heart. Coronary anastomoses constructed with sutures that stretch substantially during each pressure cycle may reduce the occurrence of a pseudoaneurysm.…”
Section: Introductionmentioning
confidence: 99%