2009
DOI: 10.1590/s0100-69912009000200004
|View full text |Cite
|
Sign up to set email alerts
|

Termocoagulação endoscópica do esôfago de Barrett com plasma de argônio sob diferentes potências: análise histopatológica e de sintomas pós-procedimento

Abstract: There are evidences that the 70W potency argon plasma coagulation for BE leads to a lower incidence of residual specialized columnar metaplasia under the new scamous epithelium.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 27 publications
0
1
0
Order By: Relevance
“…In this case, no histological changes suggested neoplasia in patients undergoing APC. Dotti et al [25] showed a correlation between potency and level of mucosal involvement (depth), analyzed by histology, after applying APC in esophageal mucosa affected by Barrett's esophagus. They observed that the higher the potency, the greater the deep mucosa; with 90 % of patients undergoing APC with 70 W, the deep mucosa was cauterized, different from patients with an APC 50 W rate of 60 %.…”
Section: Gastrojejunal Anastomosis Diametermentioning
confidence: 99%
“…In this case, no histological changes suggested neoplasia in patients undergoing APC. Dotti et al [25] showed a correlation between potency and level of mucosal involvement (depth), analyzed by histology, after applying APC in esophageal mucosa affected by Barrett's esophagus. They observed that the higher the potency, the greater the deep mucosa; with 90 % of patients undergoing APC with 70 W, the deep mucosa was cauterized, different from patients with an APC 50 W rate of 60 %.…”
Section: Gastrojejunal Anastomosis Diametermentioning
confidence: 99%
“…Table 1 summarizes the baseline characteristics of the included studies. Twenty studies included standard APC (ranging from 30 to 60 W), [11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27][28][29][30] eight studies included high-power APC (>60 W), [31][32][33][34][35][36][37][38] two included mixed wattage, 39,40 and eight studies included on hybrid APC. [41][42][43][44][45][46][47][48] Among studies reporting high-power APC, one used 65 to 70 W, 11 two used 70 W, 35,38 four used 90 W, 32,33,36,37 and one used 150 W. 34 Supplementary Table 1 shows the detailed study quality analysis using a modified Newcastle-Ottawa Scale.…”
Section: Baseline Characteristics With Quality Assessmentmentioning
confidence: 99%