Testing protection relays based on IEC 61850 in Substation Automation Systems

Abstract: IEC 61850 standard has achieved the required development for the communication in the Substation Automation Systems (SASs) by allowing to apply the high-speed peer-to-peer communications that is the basis of metering, control and protection applications in SASs. Nevertheless, an appropriate test method for performance testing of IEC 61850 compatible with protection relays and systems is an urgent need to ensure the protection functions of relays will operate as designed. This paper reviews requirements (softwa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
2
0
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 11 publications
(13 reference statements)
0
2
0
1
Order By: Relevance
“…Pengambilan datanya ini biasanya menggunakan hardwired, sedangkan untuk gardu induk yang sudah digital (Digital Substation), pengambilannya menggunakan protokol IEC 61850 (GOOSE dan Sample Value/SV). GOOSE dan SV telah terbukti sangat andal untuk digunakan dalam berbagai aplikasi [11]. GOOSE menawarkan banyak manfaat, termasuk kecepatan, pengurangan kabel, dan fleksibilitas [12].…”
Section: Landasan Teoriunclassified
“…Pengambilan datanya ini biasanya menggunakan hardwired, sedangkan untuk gardu induk yang sudah digital (Digital Substation), pengambilannya menggunakan protokol IEC 61850 (GOOSE dan Sample Value/SV). GOOSE dan SV telah terbukti sangat andal untuk digunakan dalam berbagai aplikasi [11]. GOOSE menawarkan banyak manfaat, termasuk kecepatan, pengurangan kabel, dan fleksibilitas [12].…”
Section: Landasan Teoriunclassified
“…Obserwowane różnice wynikają z rozbieżności działania przekaźnika P446 oraz opóźnień wprowadzanych przez zwrotne wiadomości GOOSE -a dokładniej czas ich przetwarzania wewnątrz samego przekaźnika [12]…”
Section: Wyniki Badańunclassified
“…The IEC 61850 communication offers various opportunities for advancing protection relay speed, safety, reliability, and sensitivity [8]. The IEC 61850 standard defines the format and content of GOOSE messages, including data object models, data types, and communication protocols [9,10]. For IEC 61850 GOOSE communication messages to be published via the Ethernet network, the Real-Time Digital Simulation (RTDS) uses the GTNET-GSE card, which enables transmitting and receiving signals from the IED relays [11].…”
Section: Introductionmentioning