2003
DOI: 10.1103/physrevlett.90.060402
|View full text |Cite
|
Sign up to set email alerts
|

Tests of Lorentz Invariance using a Microwave Resonator

Abstract: The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We determine the variation of the oscillator frequency as a function of its orientation (Michelson-Morley test) and of its velocity (Kennedy-Thorndike test) with respect to a preferred frame candidate. We constrain the corresponding parameters of the Mansouri and Sexl test theory to δ − β + 1/2 ≤ 3.4 × 10 −9 and β − α − 1 ≤ 4.1 × 10 −7 which is of the same o… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
66
0
2

Year Published

2004
2004
2012
2012

Publication Types

Select...
5
3
1

Relationship

1
8

Authors

Journals

citations
Cited by 145 publications
(70 citation statements)
references
References 27 publications
(56 reference statements)
2
66
0
2
Order By: Relevance
“…One of these is the Brillet-Hall experiment [69], which used a Fabry-Pérot laser interferometer. In a recent series of experiments, the frequencies of electromagnetic cavity oscillators in various orientations were compared with each other or with atomic clocks as a function of the orientation of the laboratory [438,254,293,20,376]. These placed bounds on −2 − 1 at the level of better than a part in 10 9 .…”
Section: Tests Of the Weak Equivalence Principlementioning
confidence: 99%
See 1 more Smart Citation
“…One of these is the Brillet-Hall experiment [69], which used a Fabry-Pérot laser interferometer. In a recent series of experiments, the frequencies of electromagnetic cavity oscillators in various orientations were compared with each other or with atomic clocks as a function of the orientation of the laboratory [438,254,293,20,376]. These placed bounds on −2 − 1 at the level of better than a part in 10 9 .…”
Section: Tests Of the Weak Equivalence Principlementioning
confidence: 99%
“…A variety of clock anisotropy experiments have been carried out to bound the electromagnetic parameters of the SME framework [227]. For example, the cavity experiments described above [438,254,293] placed bounds on the coefficients of the tensors˜e − and˜o + (see Section 2.2.4 for definitions) at the levels of 10 −14 and 10 −10 , respectively. Direct comparisons between atomic clocks based on different nuclear species place bounds on SME parameters in the neutron and proton sectors, depending on the nature of the transitions involved.…”
Section: Tests Of the Weak Equivalence Principlementioning
confidence: 99%
“…The oscillator allowed some new tests on Lorentz Invariance, up to a factor of 70 times more superior than previously [21][22][23]. The oscillator now supplies the stable frequency used to synthesize the frequencies that excite atomic transitions of the atomic clocks at SYRTE [24,25].…”
Section: Introductionmentioning
confidence: 99%
“…Such oscillators have been serving quite well for scientific experiments, and also as the flywheel of primary Cs fountain clocks. [17][18][19] However, the liquid-He bath is incompatible with field applications requiring reliable and unsurveyed operation.…”
Section: Introductionmentioning
confidence: 99%