“…About 95-96% lead and chromium are removed at lower flow rates (1.0 ml min −1 ), while this decreases with increased flow rate. The results obtained from the column experiments were applied to the wellknown bed-depth-service-time (BDST) model proposed by Hutchins [28] and it was found that the results obtained in column experiments for lead and chromium obey this model very well, which indicates the feasibility of these column experiments. The breakthrough curves (Fig.…”
“…About 95-96% lead and chromium are removed at lower flow rates (1.0 ml min −1 ), while this decreases with increased flow rate. The results obtained from the column experiments were applied to the wellknown bed-depth-service-time (BDST) model proposed by Hutchins [28] and it was found that the results obtained in column experiments for lead and chromium obey this model very well, which indicates the feasibility of these column experiments. The breakthrough curves (Fig.…”
“…Hutchins [55] presented a modification of the BohartAdams equation, which requires only three column tests to collect the necessary data. In this technique, called the bed depth service time (BDST) approach, the Bohart-Adams equation is expressed as…”
Section: Analysis and Modeling Of Column Data 3231 Analysis Basedmentioning
“…In this relation e (k ads N 0 /u)z 1, thus ln(e (k ads N 0 /u)z − 1) ∼ = k ads N 0 u Z, that is the reason why Hutchins [11] proposed the following linear relation between the column bed depth (Z) and the service time (t b ):…”
Section: Design Of the Adsorption Column Based On Bed Depth Service Timementioning
confidence: 99%
“…(3) allows to calculate the value of N 0 and thus to estimate the value of Z 0 . If there is a change in the initial solute concentration C 0 to a new value C 0 , the new values of m 0 and C x can be, respectively, obtained from the slope and the intercept according to the relations proposed by Hutchins [11]:…”
Section: Design Of the Adsorption Column Based On Bed Depth Service Timementioning
confidence: 99%
“…When the linear flow rate is changed from u to u , the new value of the slope (m x ) is obtained by Eq. (8) [11]. However the intercept remains unchanged because it depends on the inlet solute concentration C 0 :…”
Section: Design Of the Adsorption Column Based On Bed Depth Service Timementioning
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.