2013
DOI: 10.1088/1748-0221/8/09/c09010
|View full text |Cite
|
Sign up to set email alerts
|

Tetraphenyl-butadiene films: VUV-Vis optical characterization from room to liquid argon temperature

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
35
1
1

Year Published

2015
2015
2020
2020

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 20 publications
(39 citation statements)
references
References 11 publications
0
35
1
1
Order By: Relevance
“…Fig. 15 presents optical spectra of the PMT Quantum Efficiency (QE) [52,53], SiPM Photon Detection Efficiency (PDE) [35,52,54], transmittance of the ordinary and UV acrylic plate in front of the SiPM and 1PMT, respectively, and WLS hemispherical transmittance [55]. In addition, the emission spectrum of the WLS [51] is presented.…”
Section: Experimental Setup and Proceduresmentioning
confidence: 99%
See 1 more Smart Citation
“…Fig. 15 presents optical spectra of the PMT Quantum Efficiency (QE) [52,53], SiPM Photon Detection Efficiency (PDE) [35,52,54], transmittance of the ordinary and UV acrylic plate in front of the SiPM and 1PMT, respectively, and WLS hemispherical transmittance [55]. In addition, the emission spectrum of the WLS [51] is presented.…”
Section: Experimental Setup and Proceduresmentioning
confidence: 99%
“…Regarding the conversion efficiency of the TPB-based WLS, in our previous works [16,18] we used CE = 0.58 around 128 nm [51], CE = 0.40 at 300-400 nm [51,55,57] and CE = 0 above 400 nm. However, the TPB conversion efficiency at 128 nm has recently been significantly revised towards a decrease [58]: the correction factor reached 2.…”
Section: Experimental Setup and Proceduresmentioning
confidence: 99%
“…Here N e is the charge expressed in the number of electrons, drifting in the EL gap and producing proportional electroluminescence. Figure 2 presents optical spectra of the PMT Quantum Efficiency (QE) [20,21], MPPC Photon Detection Efficiency (PDE) [16,20], acrylic plate transmittance (measured by us) and WLS (TPB in polystyrene) hemispherical transmittance [22]. In addition, the EL emission spectrum of Ar doped with N 2 , namely the 2PS spectrum [7], and the emission spectrum of the WLS (TPB in polystyrene) [23] are presented.…”
Section: Experimental Setup and Measurement Proceduresmentioning
confidence: 99%
“…1. TPB is used as a wavelength shifter in noble gas detectors (NEXT [3], ArDM [4]) due to the short scintillation wavelengths of the noble gases (128 nm for Ar, 172 nm for Xe). It is used as a coating for the active surface of the photosensors and the internal walls of the detectors.…”
Section: Introductionmentioning
confidence: 99%