1999
DOI: 10.1006/jmsp.1998.7735
|View full text |Cite
|
Sign up to set email alerts
|

The 0 → 3 Overtone Band of CO: Precise Linestrengths and Broadening Parameters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
36
0

Year Published

2000
2000
2010
2010

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 43 publications
(39 citation statements)
references
References 12 publications
3
36
0
Order By: Relevance
“…Fig. 8 shows our N 2 broadening results and those of Hennigsen et al [3], both for room temperature and using a Voigt profile in the fitting routine. The two sets are in agreement within the combined estimated error bars.…”
mentioning
confidence: 84%
“…Fig. 8 shows our N 2 broadening results and those of Hennigsen et al [3], both for room temperature and using a Voigt profile in the fitting routine. The two sets are in agreement within the combined estimated error bars.…”
mentioning
confidence: 84%
“…The v = 3 ← v = 0 (11) and v = 2 ← v = 0 (20) bands of CO were used for wavenumber standards for spectra obtained with the multiple reflection cell. The corrections applied to the wavenumbers ranged from Toth et al 5 1.84(10) 1.18 (7) 18(10) Bouanich et al 6 1.75(6) 1.18(7) b 18(10) b Henningsen et al 9 1.697 (17) The slopes of plots of the corrected wavenumbers versus total gas pressure were taken as the wavenumber shift, δ(cm −1 /atm); an example of such a plot is given in Fig. 3 for the m = −14 transition.…”
Section: B Pressure Shiftsmentioning
confidence: 99%
“…The |R 3-0 | 2 value from Ref. (9) has been adjusted to account for the fact that these authors used a slightly different partition function and reported values for natural abundance rather than pure sample. The more modern measurements of |R 3-0 | 2 fall about 8.6% below the value of Toth et al (5), which is the basis of the current HITRAN CO line intensities.…”
Section: A Intensitiesmentioning
confidence: 99%
See 1 more Smart Citation
“…The fourth scan is performed with retracted mirror and measures the Fabry-Perot fringes which provide the basis for constructing a linear frequency axis. In previous investigations (11,12) the Fabry-Perot fringes were recorded in synchronism with each individual scan. Although the fringe pattern as a whole would drift over time due to temperature variations in the laboratory, this would not affect the resulting frequency axis, which is based on the separation between fringes.…”
Section: Methodsmentioning
confidence: 99%