1995
DOI: 10.1016/0167-8140(95)01571-w
|View full text |Cite
|
Sign up to set email alerts
|

The acceptability of a multileaf collimator as a replacement for conventional blocks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
20
0

Year Published

1997
1997
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 36 publications
(20 citation statements)
references
References 11 publications
0
20
0
Order By: Relevance
“…To achieve the appropriate target coverage and respect the dose constraint criteria for organs at risk, both IMRT and VMAT use many irregularly shaped fields defined by multileaf collimators (MLCs). MLCs have been routinely used in radiotherapy over the past 20 years 4, 5. Desirable MLC design characteristics include low intraleaf and interleaf transmission, a small tongue and groove effect, a small leaf width, accurate and fast leaf positioning, and most importantly, reproducibility.…”
Section: Introductionmentioning
confidence: 99%
“…To achieve the appropriate target coverage and respect the dose constraint criteria for organs at risk, both IMRT and VMAT use many irregularly shaped fields defined by multileaf collimators (MLCs). MLCs have been routinely used in radiotherapy over the past 20 years 4, 5. Desirable MLC design characteristics include low intraleaf and interleaf transmission, a small tongue and groove effect, a small leaf width, accurate and fast leaf positioning, and most importantly, reproducibility.…”
Section: Introductionmentioning
confidence: 99%
“…7 At that time, there were only a limited number of prototype 3D TP software systems in use 26 and they were still very much being developed in-house. In 1993, Webb 27 listed nine 3D TPS in use internationally most not marketed commercially.…”
Section: Ct Based Treatment Planningmentioning
confidence: 99%
“…In 2001, the Peter MacCallum Cancer Centre in Melbourne, developed an in-house 3D-coregistration software to enable CT and PET images to be coregistered on the CadPlan® TPS and a pilot study to determine the feasibility of using the software shortly followed. 41 Computer-controlled treatment delivery systems, field collimation technology such as asymmetric diaphragms, multileaf collimators (MLC), 7,42 dynamic wedge, and electronic portal imaging (EPI) made it possible to deliver more complex treatments like 3D conformal radiation therapy 23,43,44 and later IMRT. In the Australian context, linear accelerators with most of these capabilities became available from the late 1990s.…”
Section: D Treatment Planningmentioning
confidence: 99%
See 1 more Smart Citation
“…Although MLCs have been favourably compared to traditional beamshaping techniques (Fernandez, et al, 1995), they are not used dynamically under clinical conditions. Therefore, in this work the PSCs, which are deduced from the optimised IMB profiles, are used to modulate the beam intensities.…”
Section: Introductionmentioning
confidence: 99%