2024
DOI: 10.1371/journal.pone.0297110
|View full text |Cite
|
Sign up to set email alerts
|

The accuracy of 10 g monofilament use for clinical screening of diabetes peripheral neuropathy among Indian population

Animesh Hazari,
Vinaytosh Mishra,
Praveen Kumar
et al.

Abstract: Objective The purpose of this study was to test the diagnostic accuracy of the 10g monofilament to screen for diabetic peripheral neuropathy (DPN) in India. The study further assessed the effect of physical activity, footwear use, and occupation on the outcome. Methods Non-probabilistic purposive sampling was used to recruit patients with T2DM to assess the diagnostic utility of the 10 g monofilament. 160 participants were recruited divided into 4 groups. Each group consisted of 40 participants with 20 under… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 16 publications
0
1
0
Order By: Relevance
“…The MNSI consisted of two parts: a self-administered questionnaire regarding Diabetic Peripheral Neuropathy (DPN) symptoms and a brief physical examination of the foot. The study employed specific equipment for assessment, including a 128 Hz frequency tuning fork with a sensitivity of 72.5% and specificity of 88.7%, a clinical hammer with a sensitivity of 51.4% and specificity of 97.7%, and a 10-g SWM diabetic monofilament with a sensitivity of 69.7% and specificity of 87.9% 22 24 but have a limited accuracy in Indian population, further affected by occupation, socioeconomic status and religious practices 25 Figs. ( 1 , 2 , 3 ).…”
Section: Methodsmentioning
confidence: 99%
“…The MNSI consisted of two parts: a self-administered questionnaire regarding Diabetic Peripheral Neuropathy (DPN) symptoms and a brief physical examination of the foot. The study employed specific equipment for assessment, including a 128 Hz frequency tuning fork with a sensitivity of 72.5% and specificity of 88.7%, a clinical hammer with a sensitivity of 51.4% and specificity of 97.7%, and a 10-g SWM diabetic monofilament with a sensitivity of 69.7% and specificity of 87.9% 22 24 but have a limited accuracy in Indian population, further affected by occupation, socioeconomic status and religious practices 25 Figs. ( 1 , 2 , 3 ).…”
Section: Methodsmentioning
confidence: 99%