2007
DOI: 10.1007/s10554-007-9216-x
|View full text |Cite
|
Sign up to set email alerts
|

The accuracy of length measurements using different intravascular ultrasound motorized transducer pullback systems

Abstract: Accurate length measurements by intravascular ultrasound (IVUS) are necessary for stent length selection and for IVUS volumetric analysis. The comparative accuracy of commercially available transducer pullback systems--a necessity for accurate IVUS length and volume measurements--has never been studied. We evaluated the accuracy of four IVUS pullback systems by studying 180 patients (45 in each group) who had been treated with a single stent of known length. Stented lesions were located in the left anterior de… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
13
0
1

Year Published

2009
2009
2013
2013

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(14 citation statements)
references
References 15 publications
0
13
0
1
Order By: Relevance
“…On the other hand, IVUS enables observing a coronary arterial lumen from inside the vessel, which yields a direct image that includes the luminal diameter, the lesion length and the lesion morphology of the vessel. IVUS imaging using motorized pullback of the transducer provides reliable length measurement [10, 11]. There have been several studies that have compared the findings between 2D QCA and IVUS QCA [3, 12], and there is a consensus that the severity of the disease cannot accurately be determined by 2D QCA.…”
Section: Discussionmentioning
confidence: 99%
“…On the other hand, IVUS enables observing a coronary arterial lumen from inside the vessel, which yields a direct image that includes the luminal diameter, the lesion length and the lesion morphology of the vessel. IVUS imaging using motorized pullback of the transducer provides reliable length measurement [10, 11]. There have been several studies that have compared the findings between 2D QCA and IVUS QCA [3, 12], and there is a consensus that the severity of the disease cannot accurately be determined by 2D QCA.…”
Section: Discussionmentioning
confidence: 99%
“…17,22) The neurovascular system is more vulnerable to embolic ischemic complications, with more tortuous and smaller vessels. 24) Moreover, the IVUS catheters are not thin or soft enough for compatibility with intracranial navigation.…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, any length, and subsequently, any volume information depend on an accurate and consistent pullback of the ultrasound probe. While some studies have raised concerns about the accuracy of length measurements due to inconsistent pullback, 15 the authors demonstrated excellent correlation to known distances in the coronary bed, increasing our confidence in the volumetric measurements.…”
Section: Ivus-vh and Coronary Cta For Atherosclerotic Plaque Imagingmentioning
confidence: 99%