1989
DOI: 10.1118/1.596320
|View full text |Cite
|
Sign up to set email alerts
|

The accuracy of single‐seed dose superposition for I‐125 implants

Abstract: The Monte Carlo method was used to study perturbations of single I-125 seed dose distributions created by the presence of one or three neighboring seeds for the case of seeds immersed in a water phantom. Perturbation factors were determined within the geometric shadow of neighboring seeds for two-seed designs, four-seed spacings, and several choices of dose point. The results were compared to dose estimates obtained by the simple superposition of single-seed data for one- and two-plane implants. Some significa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
20
0

Year Published

1991
1991
2014
2014

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 30 publications
(21 citation statements)
references
References 0 publications
1
20
0
Order By: Relevance
“…Similarly, in computer dose calculations for interstitial implants, interseed effects are ignored. Measurements 45 and Monte Carlo calculations 46 for 125 I implants show that for the specific geometries investigated the actual peripheral dose is about 6% lower than that obtained from summing single source doses. Unlike the situation with colpostats, there are as yet insufficient data to recommend incorporating interseed effects into treatment planning systems.…”
Section: Intersource Heterogeneity and Applicator Effects On Dosementioning
confidence: 99%
“…Similarly, in computer dose calculations for interstitial implants, interseed effects are ignored. Measurements 45 and Monte Carlo calculations 46 for 125 I implants show that for the specific geometries investigated the actual peripheral dose is about 6% lower than that obtained from summing single source doses. Unlike the situation with colpostats, there are as yet insufficient data to recommend incorporating interseed effects into treatment planning systems.…”
Section: Intersource Heterogeneity and Applicator Effects On Dosementioning
confidence: 99%
“…By considering Eqs. (2), (6), and (7) together, we can find that dose calculation under tissue heterogeneity conditions is transformed to a process of determining the dose calculation parameters of the source in some homogeneous medium. The method to determine these parameters has been discussed in many articles.…”
Section: Revised Dose Correction Formulasmentioning
confidence: 99%
“…Nevertheless, this calculation model has ignored several important factors: namely (a) seed anisotropy introduced by the real 3-D line source, (b) interseed effect caused by numerous sources that are available simultaneously, and (c) tissue heterogeneity which is substantial in actual clinical implants. Although there have been numerous detailed works [4][5][6][7][8][9][10] available focusing on (a) and (b), studies on the tissue heterogeneous effect are not common and detailed. 11,12) Here, we conduct research and discuss the tissue heterogeneous effect on dose distribution for a single source.…”
Section: Introductionmentioning
confidence: 99%
“…In brachytherapy the need of validation is high; in interstitial brachytherapy, the effects of source-to-source shielding (1,2) should be considered and shielded applicators in intracavitary brachytherapy are used the dose distributions should be validated (3). Several dosimetry systems have been used to perform accurate dose measurements.…”
Section: Introductionmentioning
confidence: 99%