Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Background While measuring meniscal extrusion quantitatively is an early risk factor for knee osteoarthritis (KOA), the biomechanics involved in this process are not well understood. This study aimed to investigate the effects of varying degrees of medial and lateral meniscal extrusion and their material softening on knee osteoarthritis progression. Methods Finite element analysis (FEA) was utilized to simulate varying degrees of meniscal extrusion (1–5 mm) in 72 knee joint models, representing progressive meniscal degeneration and material softening due to injury. Changes in von Mises stress of the cartilage and menisci and the load distribution on the tibial plateau’s meniscus and cartilage were studied under balanced standing posture in both healthy and injured knees, and statistical analysis was performed using Spearman correlation. Results Compared to healthy knees, peak stress in medial compartment tissues increased by over 40% with 4 mm of medial meniscus extrusion, and in lateral compartment tissues with 2 mm of lateral meniscus extrusion. Meniscus extrusion reduced the contact load between the meniscus and femoral cartilage but increased it between the tibial and femoral cartilages, with a maximum increase up to fivefold. Spearman correlation analysis indicated that meniscal extrusion significantly affected peak stress and contact loads in the respective knee compartment ( p < 0.001), with a lesser impact on the opposite compartment. Notably, medial meniscal extrusion also significantly increased peak stress in the lateral tibial cartilage ( p < 0.05). Conclusions The quantitative analysis revealed that meniscal extrusion significantly affected the biomechanics of soft tissues within the same compartment, with limited impact on the opposite side. Specifically, Medial extrusion beyond 4 mm significantly affected the biomechanics of the medial compartment, while lateral extrusion over 2 mm had a similar impact on the lateral compartment. Meniscal softening, without altering joint contact characteristics, primarily affected the biomechanics of the meniscus itself, with minimal impact on other soft tissues.
Background While measuring meniscal extrusion quantitatively is an early risk factor for knee osteoarthritis (KOA), the biomechanics involved in this process are not well understood. This study aimed to investigate the effects of varying degrees of medial and lateral meniscal extrusion and their material softening on knee osteoarthritis progression. Methods Finite element analysis (FEA) was utilized to simulate varying degrees of meniscal extrusion (1–5 mm) in 72 knee joint models, representing progressive meniscal degeneration and material softening due to injury. Changes in von Mises stress of the cartilage and menisci and the load distribution on the tibial plateau’s meniscus and cartilage were studied under balanced standing posture in both healthy and injured knees, and statistical analysis was performed using Spearman correlation. Results Compared to healthy knees, peak stress in medial compartment tissues increased by over 40% with 4 mm of medial meniscus extrusion, and in lateral compartment tissues with 2 mm of lateral meniscus extrusion. Meniscus extrusion reduced the contact load between the meniscus and femoral cartilage but increased it between the tibial and femoral cartilages, with a maximum increase up to fivefold. Spearman correlation analysis indicated that meniscal extrusion significantly affected peak stress and contact loads in the respective knee compartment ( p < 0.001), with a lesser impact on the opposite compartment. Notably, medial meniscal extrusion also significantly increased peak stress in the lateral tibial cartilage ( p < 0.05). Conclusions The quantitative analysis revealed that meniscal extrusion significantly affected the biomechanics of soft tissues within the same compartment, with limited impact on the opposite side. Specifically, Medial extrusion beyond 4 mm significantly affected the biomechanics of the medial compartment, while lateral extrusion over 2 mm had a similar impact on the lateral compartment. Meniscal softening, without altering joint contact characteristics, primarily affected the biomechanics of the meniscus itself, with minimal impact on other soft tissues.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.