2013
DOI: 10.1507/endocrj.ej12-0230
|View full text |Cite
|
Sign up to set email alerts
|

The arginine and GHRP-2 tests as alternatives to the insulin tolerance test for the diagnosis of adult GH deficiency in Japanese patients: A comparison

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 31 publications
0
8
0
Order By: Relevance
“…A GH cutoff value of 9 ng/mL with GHRP-2 corresponded to a GH value of 1.8 ng/mL with the insulin tolerance test when the GH value was calibrated with recombinant World Health Organization 98/574 standard [ 22 ]. Although the GHRP-2 test is not included in the Endocrine Society Guidelines [ 23 ], the GHRP-2 test is considered to be safe [ 24 ] and widely used to diagnose SGHD in Japan because of its high sensitivity and specificity compared with the insulin tolerance test [ 25 ]. The peak GH concentration after GHRP-2 stimulation was ≥9 ng/mL in 40 patients (SGHD − ) and <9 ng/mL in 32 patients (SGHD + ).…”
Section: Methodsmentioning
confidence: 99%
“…A GH cutoff value of 9 ng/mL with GHRP-2 corresponded to a GH value of 1.8 ng/mL with the insulin tolerance test when the GH value was calibrated with recombinant World Health Organization 98/574 standard [ 22 ]. Although the GHRP-2 test is not included in the Endocrine Society Guidelines [ 23 ], the GHRP-2 test is considered to be safe [ 24 ] and widely used to diagnose SGHD in Japan because of its high sensitivity and specificity compared with the insulin tolerance test [ 25 ]. The peak GH concentration after GHRP-2 stimulation was ≥9 ng/mL in 40 patients (SGHD − ) and <9 ng/mL in 32 patients (SGHD + ).…”
Section: Methodsmentioning
confidence: 99%
“…To further investigate the pituitary function, CRH (100 μg), TRH (200 μg), GnRH (100 μg) and GHRP-2 (100 μg) load tests were performed (Fig. 2) in the previously described manner [11][12][13][14] to confirm normality of not only basal, but also responsive secretion of pituitary hormones other than ACTH [11]. The adrenal response was markedly abnormal; the low baseline cortisol level of 0.2 μg/dl stayed at the same level at all the time points up to 120 min.…”
Section: Case Presentationmentioning
confidence: 99%
“…A GH cut-off value of 9 ng/mL with GHRP-2 corresponded to a GH value of 1.8 ng/mL with an ITT when the GH value was calibrated with the recombinant WHO 98/574 standard [13]. Although the GHRP-2 test was not included in the Endocrine Society Guidelines [14], the GHRP-2 test is considered safe [15] and is widely employed to diagnose severe GHD in Japan owing to its high sensitivity and specificity when compared to ITT [16].…”
Section: Gh-releasing Peptide-2 Testmentioning
confidence: 99%