OBJECTIVE
In this study, the authors aimed to describe a new technique of sacroiliac joint (SIJ) fusion using a robotic navigation guidance system and to document clinical results with patient-reported visual analog scale (VAS) scores.
METHODS
Patients diagnosed with SIJ dysfunction were surgically treated using 2 hydroxyapatite (HA)–coated, threaded screws with the aid of the robotic navigation system. In a total of 36 patients, 51 SIJs were fused during the study period. Patients’ VAS scores were used to determine clinical improvement in pain. Postoperative imaging at routine intervals during the follow-up period was also performed for assessment of radiological fusion. In addition, complication events were recorded, including reoperations.
RESULTS
All 36 patients had successful fusion evidenced by both CT and clinical assessment at the final follow-up. Two patients underwent reoperation because of screw loosening. The mean preoperative VAS score was 7.2 ± 1.1, and the mean 12-month postoperative VAS score was 1.6 ± 1.46. This difference was statistically significant (p < 0.05) and demonstrated a substantial clinical improvement in pain.
CONCLUSIONS
Robotic navigation–assisted SIJ fusion using 2 HA-coated, threaded screws placed across the joint was an acceptable technique that demonstrated reliable clinical results with a significant improvement in patient-reported VAS pain scores.