2020
DOI: 10.1016/j.wneu.2020.09.063
|View full text |Cite
|
Sign up to set email alerts
|

The Brain is Not Flat: Conformal Electrode Arrays Diminish Complications of Subdural Electrode Implantation, A Series of 117 Cases

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
24
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
4

Relationship

6
3

Authors

Journals

citations
Cited by 23 publications
(24 citation statements)
references
References 31 publications
0
24
0
Order By: Relevance
“…Electrode Implantation and Data Recording: Data were acquired from either subdural grid electrodes (SDEs; 18 patients), stereotactically placed depth electrodes (sEEGs; 47 patients) or high-density depth electrodes (hdsEEGs; 6 patients) (Figure 1C,D). SDEs were subdural platinum-iridium electrodes embedded in a silicone elastomer sheet (PMT Corporation; top-hat design; 3mm diameter cortical contact), surgically implanted via a craniotomy (Conner et al 2011;Pieters et al 2013;Tandon 2012;Tong et al 2020). sEEGs were implanted using a Robotic Surgical Assistant (ROSA; Medtech, Montpellier, France) (Rollo et al 2020;Tandon et al 2019).…”
Section: Methodsmentioning
confidence: 99%
“…Electrode Implantation and Data Recording: Data were acquired from either subdural grid electrodes (SDEs; 18 patients), stereotactically placed depth electrodes (sEEGs; 47 patients) or high-density depth electrodes (hdsEEGs; 6 patients) (Figure 1C,D). SDEs were subdural platinum-iridium electrodes embedded in a silicone elastomer sheet (PMT Corporation; top-hat design; 3mm diameter cortical contact), surgically implanted via a craniotomy (Conner et al 2011;Pieters et al 2013;Tandon 2012;Tong et al 2020). sEEGs were implanted using a Robotic Surgical Assistant (ROSA; Medtech, Montpellier, France) (Rollo et al 2020;Tandon et al 2019).…”
Section: Methodsmentioning
confidence: 99%
“…Electrode Implantation and Data Recording: Data were acquired using either subdural grid electrodes (SDEs; 14 patients) or stereotactically placed depth electrodes (sEEGs; 68 patients). SDEs were subdural platinum-iridium electrodes embedded in a silicone elastomer sheet (PMT Corporation; tophat design; 3mm diameter cortical contact), surgically implanted via a craniotomy following previously described methods (Pieters et al, 2013;Tandon, 2012;Tong et al, 2020). sEEGs were implanted using a Robotic Surgical Assistant (ROSA; Medtech, Montpellier, France) (Rollo et al, 2020;Tandon et al, 2019).…”
Section: Methodsmentioning
confidence: 99%
“…1B). SDEs were subdural platinum-iridium electrodes embedded in a silicone elastomer sheet (PMT Corporation; top-hat design; 3mm diameter cortical contact), and were surgically implanted via a craniotomy (Conner et al, 2011;Pieters et al, 2013;Tong et al, 2020;Kohlhase et al, 2021). sEEGs were implanted using a Robotic Surgical Assistant (ROSA; Medtech, Montpellier, France) (Rollo et al, 2020;McCarty et al, 2021).…”
Section: Methodsmentioning
confidence: 99%