1999
DOI: 10.1007/bf03161933
|View full text |Cite
|
Sign up to set email alerts
|

The bruker high-frequency-EPR system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
38
0

Year Published

2008
2008
2017
2017

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 46 publications
(38 citation statements)
references
References 21 publications
0
38
0
Order By: Relevance
“…Significant developments of high-field quasi-optical ESR are ongoing, 32,33,[36][37][38][39][40] where cw ESR has evolved up to f hν = 750 GHz 41 and free electron lasers (FEL) can provide highest irradiation power (several kW) in pulsed or quasi-cw high-field ESR. [42][43][44][45] However, these spectrometers are highly specialized and operate in one dedicated high-field environment, 41 and a very recent commercial system provides a high ESR sensitivity but narrow (0.2 T) field sweep range.…”
Section: Improving Electron Spin Resonance (Esr)mentioning
confidence: 99%
“…Significant developments of high-field quasi-optical ESR are ongoing, 32,33,[36][37][38][39][40] where cw ESR has evolved up to f hν = 750 GHz 41 and free electron lasers (FEL) can provide highest irradiation power (several kW) in pulsed or quasi-cw high-field ESR. [42][43][44][45] However, these spectrometers are highly specialized and operate in one dedicated high-field environment, 41 and a very recent commercial system provides a high ESR sensitivity but narrow (0.2 T) field sweep range.…”
Section: Improving Electron Spin Resonance (Esr)mentioning
confidence: 99%
“…At lower frequencies , it has been demonstrated that the resonator cylinder itself can be formed from a ''ribbon coil'' [58]. It should be noted also that at W-band frequencies a split pair magnet can be used, so that the TE 011 resonator can be oriented vertically, thus enabling top loading of the sample [25,26].…”
Section: Single-mode Resonators (Te 011 )mentioning
confidence: 99%
“…By minimizing the inductive contact between the main and sweep coils, some components of the non-linearity can be suppressed. The field hysteresis can be minimized by letting the magnet power supply use ''current jumps'' at the start and end of a sweep [25,26]. In the Bruker W-band system, the magnetic field is calibrated for a multiple of sweep rates using an NMR gaussmeter in the free bore of the magnet.…”
Section: Magnet Technologymentioning
confidence: 99%
See 2 more Smart Citations