The Clinical Feasibility of Newly Developed Thin Flat-Type Bioresorbable Osteosynthesis Devices for the Internal Fixation of Zygomatic Fractures

Abstract: Introduction:In recent years, bioresorbable plates have undergone remarkable development. However, there has been no attendant improvement in their strength, because strength requires thickness, and complications such as palpability are related to the thickness of bioresorbable plate systems. In this clinical study, we compared the surgical management of zygomatic fractures using newly developed thinner bioresorbable materials or conventional titanium miniplates.Methods:Twelve patients with zygomatic fractures… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
31
0
2

Year Published

2018
2018
2023
2023

Publication Types

Select...
3
2
1

Relationship

1
5

Authors

Journals

citations
Cited by 27 publications
(33 citation statements)
references
References 22 publications
0
31
0
2
Order By: Relevance
“…The resulting metabolites should not cause any local or systemic problems. Additionally, the amount of material required must be small, and the material itself must be flexible enough to be applied at various maxillofacial bone sites [16] , [17] , [18] , [19] . These aforementioned three resorbable materials, PGA, PLLA, and PDLA, have been commonly well introduced for the products [13] , [17] ( Fig.…”
Section: Variety Of Bioresorbable Osteosynthesis Materialsmentioning
confidence: 99%
See 4 more Smart Citations
“…The resulting metabolites should not cause any local or systemic problems. Additionally, the amount of material required must be small, and the material itself must be flexible enough to be applied at various maxillofacial bone sites [16] , [17] , [18] , [19] . These aforementioned three resorbable materials, PGA, PLLA, and PDLA, have been commonly well introduced for the products [13] , [17] ( Fig.…”
Section: Variety Of Bioresorbable Osteosynthesis Materialsmentioning
confidence: 99%
“…In a clinical setting, the total resorption time of PLLA appears to be over 3.5 years [27] , [28] . Two PLLA devices, FixsorbMX ® (TEIJIN Medical Corp., Osaka, Japan) and GrandFix ® (GUNZE, Kyoto, Japan), have been used in maxillofacial bone surgery [13] , [16] . Reported problems include insufficient intensity of materials, foreign-body reactions, and a late-degradation tissue response [16] , [27] , [28] .…”
Section: Variety Of Bioresorbable Osteosynthesis Materialsmentioning
confidence: 99%
See 3 more Smart Citations