1957
DOI: 10.1039/an9578200336
|View full text |Cite
|
Sign up to set email alerts
|

The colorimetric determination of cadmium, chromium, copper, iron, lead, manganese, nickel and zinc in sewage and industrial wastes

Abstract: The more commonly occurring metallic salts in industrial effluents are those of cadmium, chromium, copper, iron, lead, manganese, nickel and zinc, and their determination in concentrations as low as 0.1 p.p.m. is necessary. Various simple colorimetric procedures were tested, and the amount of interference caused by other metal ions was noted and, if possible, eliminated. As well as being suitable for measurement in photo-electric absorptiometers, the colours can be measured in visual colorimeters or by visual … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

1975
1975
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…The chloride matrix may disturb the reaction of Cr( vi ) with DPCI, leading to the formation of the Cr( iii )–DPCO complex. 40 It also interferes with the oxidation of chromium by KMnO 4 as Cl − ions are oxidized to Cl 2 . A preliminary study was performed based on spectrophotometric determination of Cr in diluted therapeutic brine spiked with Cr( vi ) standard to obtain the final concentration of 0.1 μg mL −1 .…”
Section: Resultsmentioning
confidence: 99%
“…The chloride matrix may disturb the reaction of Cr( vi ) with DPCI, leading to the formation of the Cr( iii )–DPCO complex. 40 It also interferes with the oxidation of chromium by KMnO 4 as Cl − ions are oxidized to Cl 2 . A preliminary study was performed based on spectrophotometric determination of Cr in diluted therapeutic brine spiked with Cr( vi ) standard to obtain the final concentration of 0.1 μg mL −1 .…”
Section: Resultsmentioning
confidence: 99%
“…Methods generally suffer from the interfering metal ions and need for different assay protocols, modified synthesized ligands, and absorption wavelengths. Thus, each metal ion requires its own assay protocol, incubation times, and reagents. Fluorometric methods utilize specific fluoroionophores containing a receptor with metal binding site and fluorescent reporter. The fluoroionophores based on the receptors, such as cryptands, , (aza-)­crown ethers, EDTA-derivatives, BAPTA, , nitrilotriacetic acid, or dipicolylamine, have been developed as selective for each analyte metal ion.…”
mentioning
confidence: 99%