2006
DOI: 10.1007/s10527-006-0046-2
|View full text |Cite
|
Sign up to set email alerts
|

The computerized motion meter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
4

Year Published

2016
2016
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 4 publications
0
2
0
4
Order By: Relevance
“…The following parameters were evaluated: duration of the movement cycle (in ms) was measured as the mean time of lever movement from one marker to another and back; time to change the motor stereotype (in ms) was measured as the time to achieve the required accuracy of movement in the new amplitude mode; the error of sensory correction of flexors (in %) and extensors (in %) was determined as the ratio of the mean deviation from the specified movement range boundaries to the total amplitude of lever movement for the entire cycle; smoothness of movement (in%) is the contribution of the main harmonic in the Fourier spectrum of the movement, motor asymmetry (in%) ( Figure 2 B), and the time of a simple sensorimotor reaction to visual and acoustic stimuli (in ms) measured as the time from stimulus to the beginning of lever movement from the initial point ( Figure 2 C). A detailed description of the device and the formula for calculating the estimated indicators is given in the article [ 24 ].…”
Section: Methodsmentioning
confidence: 99%
“…The following parameters were evaluated: duration of the movement cycle (in ms) was measured as the mean time of lever movement from one marker to another and back; time to change the motor stereotype (in ms) was measured as the time to achieve the required accuracy of movement in the new amplitude mode; the error of sensory correction of flexors (in %) and extensors (in %) was determined as the ratio of the mean deviation from the specified movement range boundaries to the total amplitude of lever movement for the entire cycle; smoothness of movement (in%) is the contribution of the main harmonic in the Fourier spectrum of the movement, motor asymmetry (in%) ( Figure 2 B), and the time of a simple sensorimotor reaction to visual and acoustic stimuli (in ms) measured as the time from stimulus to the beginning of lever movement from the initial point ( Figure 2 C). A detailed description of the device and the formula for calculating the estimated indicators is given in the article [ 24 ].…”
Section: Methodsmentioning
confidence: 99%
“…и компьютеризированный измеритель движений (КИД, рекомендован МЗ РФ к применению в медицинской практике, прот. № 4 от 11.09.02), обладающие высокой пропускной способностью (до 10-12 идентификаций в час), изготовлены в варианте, удобном для транспортировки и адаптированы к условиям выездных исследований [14,15].…”
Section: методология экспертизы с помощью саногенетического мониторингаunclassified
“…При этом обеспечивается высокая информативность при тестировании функциональных резервов организма с помощью унифицированной стандартизированной методикой, а объективность получаемых результатов -единым программным обеспечением. Результаты саногенетического мониторинга включают элементы физического, психического, санитарно-гигиенического и медицинского мониторинга [6,11,15]. Для понимания проблемы безопасности использования магнитолевитационного транспорта мы исходим из отсутствия отрицательного влияния на здоровье, которое определяется как «состояние организма, обеспечивающее оптимальное выполнение его функций в необходимой мере для продуктивных отношений со средой» [10].…”
unclassified
“…Багато вітчизняних та зарубіжних вчених використовують діагностику сенсомоторної функції для вивчення когнітивних процесів [33,6,15], оцінки функціонального стану ЦНС [32,34,36], сенсорної чутливості [22,31], розвитку моторики [23,36,21], психофізіологічних і нейрофізіологічних параметрів функціонування головного мозку [9,14,17]. Завдяки своїй простоті і інформативності, сенсомоторні тести все частіше використовуються в діагностиці порушень психофізичного розвитку дітей [8,19,22,24,26,28,30,35], при захворюваннях і травмах ЦНС [13,32].…”
Section: актуальністьunclassified