2015
DOI: 10.1016/j.enbuild.2014.09.065
|View full text |Cite
|
Sign up to set email alerts
|

The concept of an integrated performance monitoring system for promotion of energy awareness in buildings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
15
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 16 publications
(15 citation statements)
references
References 30 publications
0
15
0
Order By: Relevance
“…The greenhouse effect has drawn increasing attention around the world, and the greenhouse gas emission of architectures cannot be ignored 40 . In this paper, the UPCDE shown in Equation ) is used to assess the level of carbon dioxide emission. italicUPCDE=CDEng+CDEegQitalicsup,c+Qitalicsup,h+Qitalicsup,italichw+Qitalicsup,e, where CDE ng and CDE eg represent the CO 2 emissions of natural gas combustion and electricity generation process, respectively.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The greenhouse effect has drawn increasing attention around the world, and the greenhouse gas emission of architectures cannot be ignored 40 . In this paper, the UPCDE shown in Equation ) is used to assess the level of carbon dioxide emission. italicUPCDE=CDEng+CDEegQitalicsup,c+Qitalicsup,h+Qitalicsup,italichw+Qitalicsup,e, where CDE ng and CDE eg represent the CO 2 emissions of natural gas combustion and electricity generation process, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…The greenhouse effect has drawn increasing attention around the world, and the greenhouse gas emission of architectures cannot be ignored. 40 In this paper, the UPCDE shown in Equation 33is used to assess the level of carbon dioxide emission.…”
Section: Ecological Indicesmentioning
confidence: 99%
“…Only 10 papers focus on EMS in non-residential buildings, such as hotels or office buildings. 4,38,59,62,68,72,84,91,97,98 Photovoltaic systems and battery storage are also frequently considered, with 64% and 56% respectively. The sector coupling of electricity and heat by means of heat pumps or CHP units is less relevant and is dealt with in only 13% and 5% of the literature.…”
Section: Considered Componentsmentioning
confidence: 99%
“…The overall system is organized into five different layers devoted to energy measurement, data transmission through a dedicated bus, a data collector layer in charge of sending sensed data to a storage layer on the Internet, and a storage layer, in charge to provide easy access to the collected data for producing charts and summary statistics at different detailed levels. The solution presented in [10] consists of three modules comprising data acquisition and processing, a knowledge repository and a performance analysis system devoted to energy consumption prediction and modeling and decision support. Indeed the authors provide an overview of the proposed solution although some of the fundamental aspects characterizing the monitoring campaign are missing (e.g., missing and erroneous values detection and handling).…”
Section: Related Workmentioning
confidence: 99%