2013
DOI: 10.3109/10837450.2013.867448
|View full text |Cite
|
Sign up to set email alerts
|

The critical role of NIR spectroscopy and statistical process control (SPC) strategy towards captopril tablets (25 mg) manufacturing process understanding: a case study

Abstract: In this work, near-infrared spectroscopy (NIRS) method was used to evaluate the uniformity of dosage units of three captopril 25 mg tablets commercial batches. The performance of the calibration method was assessed by determination of Q value (0.9986), standard error of estimation (C-set SEE = 1.956), standard error of prediction (V-set SEP = 2.076) as well as the consistency (106.1%). These results indicated the adequacy of the selected model. The method validation revealed the agreement of the reference high… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
1
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 15 publications
0
1
0
Order By: Relevance
“…When it is between 1.34 and 1.99, the process is considered suitable; values between 1.0 and 1.33 show that the process requires corrective action, and values less than 1.0 denote a non-capable process. If it is equal to 1.0, then 99.73 % of the values lie within the specification limits (Dal Curtivo et al, 2015). Thus, 0.27 % of the units manufactured may be out of specification (example: in 1,000,000 units manufactured, 2,700 units OOS).…”
Section: Process Capability Evaluationmentioning
confidence: 99%
See 1 more Smart Citation
“…When it is between 1.34 and 1.99, the process is considered suitable; values between 1.0 and 1.33 show that the process requires corrective action, and values less than 1.0 denote a non-capable process. If it is equal to 1.0, then 99.73 % of the values lie within the specification limits (Dal Curtivo et al, 2015). Thus, 0.27 % of the units manufactured may be out of specification (example: in 1,000,000 units manufactured, 2,700 units OOS).…”
Section: Process Capability Evaluationmentioning
confidence: 99%
“…Cp and Cpk were 1. 43 and 1.27 and 1.69 and 1.83, respectively (de Souza Botelho et al, 2011;Dal Curtivo et al, 2015).…”
Section: Process Stability Evaluationmentioning
confidence: 99%
“…Near‐infrared (NIR) spectroscopy has proven to be a successful analytical tool in measuring chemical and physical properties in‐line due to its non‐destructive nature, speed of analysis and ease of implementation in manufacturing environments 1–9 . Though NIR spectroscopy has low selectivity, it can be combined with multivariate modelling techniques such as principal component analysis (PCA) or partial least squares (PLS) to extract the relevant information and develop predictive models.…”
Section: Introductionmentioning