1969
DOI: 10.1016/0375-9474(69)90562-4
|View full text |Cite
|
Sign up to set email alerts
|

The decay of 214Pb and other 226Ra daughters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
12
1

Year Published

1973
1973
2007
2007

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 38 publications
(16 citation statements)
references
References 13 publications
3
12
1
Order By: Relevance
“…5, was about 300 h. The system had a detection limit of ~0.0002% for 7 rays with energies above 2 MeV. The 7-ray intensities for lines with energies above 3 MeV are given in Table 2; previous results [5,6] are listed for comparison. Features A and B of Fig.…”
Section: Experimental Arrangement and Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…5, was about 300 h. The system had a detection limit of ~0.0002% for 7 rays with energies above 2 MeV. The 7-ray intensities for lines with energies above 3 MeV are given in Table 2; previous results [5,6] are listed for comparison. Features A and B of Fig.…”
Section: Experimental Arrangement and Resultsmentioning
confidence: 99%
“…Although we have not observed any of these transitions in our experiments, we have been able to extract upper limits to the intensities for most of them. Coincidence measurements [5] withdrawn (see Table 1) ** y ray reported in I-5] unless otherwise stated *** The type of experiment is indicated in parentheses; y-singles; 7 y-coincidence a From Ref. 8 From Ref.…”
Section: Experimental Arrangement and Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Some measurements of X-ray data were be found in the literature for Ra-226 [6,17,29], Pb-214 [4,6] and Bi-214 [6]. In the case of Ra-226 (table 5), the recommended data and de Pinho values [29] are significantly greater than those measured by Delgado [17] and Schötzig [6].…”
Section: Comparison With X-ray Measurements and Determination Of Q-vamentioning
confidence: 99%
“…The recommended values for the relative gamma-ray emission intensities are the weighted means of the data sets found in the literature dating from 1969 to 2004 [4][5][6][7][8][9][10][11][12][13][14][15][16][17][18], calculated using the LWEIGHT computer code [19]. When necessary the uncertainties quoted by the authors were increased to achieve The transition probabilities for all gamma-rays were calculated using the absolute gamma-ray emission intensities and the relevant internal conversion coefficients (ICCs).…”
Section: Emission and Transition Probabilities Of The Major Gamma-raysmentioning
confidence: 99%