2011
DOI: 10.1002/sca.20225
|View full text |Cite
|
Sign up to set email alerts
|

The delimitation of the workspace accuracy in coordinate measuring technique

Abstract: Dimensional measurements based on coordinate metrology are widely used for product verification, process control and dimensional faults root causes diagnostics of various manufacturing processes. In this study, the results of the measuring surface scanning of coordinate measuring machine with the prototype of optoelectronic device have been presented. The presented device is able to determine actual (real) inaccuracy of the CMM in two axes (X, Y). The prototype scanning device is installed in the measuring pro… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2012
2012
2012
2012

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(8 citation statements)
references
References 8 publications
0
8
0
Order By: Relevance
“…In order to put the proposed solution into widespread use, a number of significant changes have been introduced. First of all, the conception of the CMM error‐correcting procedure (Swornowski, ) has been altered. The most significant change was relying on the results of the “classic” acceptance and reverification tests performed in accordance with the ISO 10360–2 standard (ISO, ).…”
Section: Modernization Of the Device And Integration With The Renishamentioning
confidence: 99%
See 4 more Smart Citations
“…In order to put the proposed solution into widespread use, a number of significant changes have been introduced. First of all, the conception of the CMM error‐correcting procedure (Swornowski, ) has been altered. The most significant change was relying on the results of the “classic” acceptance and reverification tests performed in accordance with the ISO 10360–2 standard (ISO, ).…”
Section: Modernization Of the Device And Integration With The Renishamentioning
confidence: 99%
“…(B)) was constructed, in which the Renishaw joint system was reproduced. The merit of this solution is the rigid connection of the PS‐20 device with the CMM (similarly as in the first project [Swornowski, ]), enabling to determine the CMM errors explicitly, which is the basis for the corrective actions. Certain data distortions occurring in the probing system presented in Figure (C) can be entirely compensated on the basis of the reference result (PAA1; Fig.…”
Section: Modernization Of the Device And Integration With The Renishamentioning
confidence: 99%
See 3 more Smart Citations