2013
DOI: 10.1016/j.rser.2013.07.057
|View full text |Cite
|
Sign up to set email alerts
|

The design and environmental evaluation of earth-to-air heat exchangers (EAHE). A literature review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

3
47
0
6

Year Published

2014
2014
2023
2023

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 145 publications
(56 citation statements)
references
References 44 publications
3
47
0
6
Order By: Relevance
“…One of them is used in the mechanical ventilation system ground air heat exchanger (earth-air heat exchanger -EAHX, EAHE, ETAHE, ATEHE) [5,6,7,8,9]. This solution, right after heat recovery from exhaust air (recuperation), allows the reduction in the energy needed to obtain the desired temperature of supply air [8].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…One of them is used in the mechanical ventilation system ground air heat exchanger (earth-air heat exchanger -EAHX, EAHE, ETAHE, ATEHE) [5,6,7,8,9]. This solution, right after heat recovery from exhaust air (recuperation), allows the reduction in the energy needed to obtain the desired temperature of supply air [8].…”
Section: Introductionmentioning
confidence: 99%
“…This solution, right after heat recovery from exhaust air (recuperation), allows the reduction in the energy needed to obtain the desired temperature of supply air [8]. The concept of ground pre-heat has already been used in the times of ancient Greece and Persia [5,6,10]. Today the first application of pre-heat were glass-buildings.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Clara Peretti et al [16] and Bisnoyia et al [17] gave an extensive literature review covering design, characteristics of EAHE, modelling adopted by several researchers etc. When the earth air heat exchanger was integrated by solar chimney which utilizes both the geothermal energy as well as the solar energy, the energy savings were greater compared to uncoupled system [18].…”
Section: Introductionmentioning
confidence: 99%
“…Chlela et al [19] concluded that a balanced ventilation system coupled with EAHE significantly reduces a building's heat demand and hence its CO 2 emissions. Clara Peretti et al [16] discussed the effect of soil cover, climate and soil composition on the performance of the EAHE and concluded that the bare surface improves the performance of the EAHE for heating whereas the wet surface is better for cooling purpose. It has also been concluded that higher water content and closely packed soil near the pipes of EAHE improves the performance of the EAHE.…”
Section: Introductionmentioning
confidence: 99%