2021
DOI: 10.1016/j.fusengdes.2020.112074
|View full text |Cite
|
Sign up to set email alerts
|

The design of Multiple Plasma Simulation Linear Device

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 39 publications
0
8
0
Order By: Relevance
“…In the MPS-LD device, the auxiliary heating for both ions and electrons is planned, and the 'Downhill' magnetic configuration, which means that the maximum axial field should be located at the upstream location, while the waveguides and window for electron Bernstein wave should be located at the lower magnetic field location, is proposed for the electron heating [3,31]. Therefore, the magnetic configuration for auxiliary heating is constructed to clarify the influence of 'Downhill' magnetic configuration on ion heating, and to predict the compatibility of electron and ion heating simultaneously.…”
Section: The Optimization Of Icrhmentioning
confidence: 99%
“…In the MPS-LD device, the auxiliary heating for both ions and electrons is planned, and the 'Downhill' magnetic configuration, which means that the maximum axial field should be located at the upstream location, while the waveguides and window for electron Bernstein wave should be located at the lower magnetic field location, is proposed for the electron heating [3,31]. Therefore, the magnetic configuration for auxiliary heating is constructed to clarify the influence of 'Downhill' magnetic configuration on ion heating, and to predict the compatibility of electron and ion heating simultaneously.…”
Section: The Optimization Of Icrhmentioning
confidence: 99%
“…The MPS-LD will be equipped with a helicon plasma source , and the diameter of the plasma beam in the first stage will be no larger than 0.14 m. This will be a steady-state discharge, and the typical discharge duration will be several hours. More details about the device can be found in [6]. The objective of the MPS-LD is to simulate plasma transport in the scrape-off layer (SOL)/divertor region and to investigate the main PMIs in the tokamak.…”
Section: Simulation Modelmentioning
confidence: 99%
“…LPD-MCC can be verified by benchmarking against the COMSOL calculation. By using the location and current of each coil in MPS-LD, see table 2 in [6], the magnetic fields calculated by LPD-MCC and COM-SOL can be compared, as shown in figure 2. It can be seen that a relative uniform magnetic field is obtained and the simulation results of the two codes are exactly the same.…”
Section: Magnetic Field Calculation and Simulation Mesh Creation For ...mentioning
confidence: 99%
See 2 more Smart Citations