2015
DOI: 10.1016/j.ijhydene.2015.01.169
|View full text |Cite
|
Sign up to set email alerts
|

The development of a hybrid PEMFC power system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
19
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
5
3
1

Relationship

2
7

Authors

Journals

citations
Cited by 44 publications
(19 citation statements)
references
References 26 publications
0
19
0
Order By: Relevance
“…(1) When the battery SOC dropped to the lower bound, SOC low , the PEMFC was switched on to provide a default current of 20 A at the highest energy efficiency [41]. (2) When the SOC continuously dropped to SOC low − 5%, the PEMFC current was increased according to the required load until the SOC was raised to SOC low + 5%, where the PEMFC provided a default current of 20 A.…”
Section: The Hybrid Power Modelmentioning
confidence: 99%
“…(1) When the battery SOC dropped to the lower bound, SOC low , the PEMFC was switched on to provide a default current of 20 A at the highest energy efficiency [41]. (2) When the SOC continuously dropped to SOC low − 5%, the PEMFC current was increased according to the required load until the SOC was raised to SOC low + 5%, where the PEMFC provided a default current of 20 A.…”
Section: The Hybrid Power Modelmentioning
confidence: 99%
“…First, setting I fcmax ¼ 40 A results in a lower cost than setting I fcmax ¼ 50 A. This is because the PEMFC efficiency is higher when running at lower loads [14]. Second, setting lower SOC low can also reduce the system costs because the battery is an effective energy buffer and avoids frequent starting of the PEMFC.…”
Section: The Impacts Of Power Management Strategiesmentioning
confidence: 99%
“…2(a): We start the PEMFC when the battery SOC reaches a low bound SOC low , and stop the PEMFC when it rises to the high limit SOC high . We control the PEMFC to provide a default current i n t e r n a t i o n a l j o u r n a l o f h y d r o g e n e n e r g y x x x ( 2 0 1 6 ) 1 e1 2 load of 20 A with the highest energy efficiency, and increase the PEMFC current output when the SOC is continuously decreasing to SOC D ( [14], Fig. 8).…”
Section: Introductionmentioning
confidence: 99%
“…Select as function constitutes an important part to the optimization problem, because the choice of different objective functions may completely alter the particles changes. We used the error function for the optimization problem: (13) where tsim is simulation time that objective is calculated from this time. Note that the more value of objective function the more optimized solution.…”
Section: Use Ica Algorithm To Adjust Controller Parametersmentioning
confidence: 99%