2018
DOI: 10.1016/j.apacoust.2018.06.017
|View full text |Cite
|
Sign up to set email alerts
|

The difficulties of simulating the acoustics of an empty rectangular room with an absorbing ceiling

Abstract:  Users may download and print one copy of any publication from the public portal for the purpose of private study or research.  You may not further distribute the material or use it for any profit-making activity or commercial gain  You may freely distribute the URL identifying the publication in the public portal If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2025
2025

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 30 publications
0
2
0
Order By: Relevance
“…On the other side, it has been concluded that the simulation of a small rectangular room with an absorbing ceiling and low scattering is inaccurate both with energy based GA simulation, i.e., ODEON, and with GA simulation which includes phase shifts on specular reflections in order to model the acoustics of the room below the Schroeder frequency [44].…”
Section: Reliability Of Ga Simulation Software For Small Sized Roomsmentioning
confidence: 99%
“…On the other side, it has been concluded that the simulation of a small rectangular room with an absorbing ceiling and low scattering is inaccurate both with energy based GA simulation, i.e., ODEON, and with GA simulation which includes phase shifts on specular reflections in order to model the acoustics of the room below the Schroeder frequency [44].…”
Section: Reliability Of Ga Simulation Software For Small Sized Roomsmentioning
confidence: 99%
“…We apply the comprehensive validation and uncertainty quantification (VUQ) framework to a simple test case of a small rectangular room with two types of boundaries: bare concrete walls on five of the surfaces, and with the sixth surface being covered by a porous material mounted on rigid backing. Previous work has indicated that this type of room is particularly diffi-cult to simulate with high precision [16]. Experiments are carried out to serve as a ground truth reference, which the simulations are compared against.…”
Section: Introductionmentioning
confidence: 99%