2023
DOI: 10.1002/mp.16809
|View full text |Cite
|
Sign up to set email alerts
|

The dirty and clean dose concept: Towards creating proton therapy treatment plans with a photon‐like dose response

Lena Heuchel,
Christian Hahn,
Jakob Ödén
et al.

Abstract: BackgroundApplying tolerance doses for organs at risk (OAR) from photon therapy introduces uncertainties in proton therapy when assuming a constant relative biological effectiveness (RBE) of 1.1.PurposeThis work introduces the novel dirty and clean dose concept, which allows for creating treatment plans with a more photon‐like dose response for OAR and, thus, less uncertainties when applying photon‐based tolerance doses.MethodsThe concept divides the 1.1‐weighted dose distribution into two parts: the clean and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2024
2024
2025
2025

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 56 publications
0
2
0
Order By: Relevance
“…In addition to the indirect approaches commonly applied in current clinical practice, various LET/RBE-guided plan optimization approaches have been proposed [ 75 , 76 , 77 , 78 , 79 , 80 , 81 , 82 , 83 , 84 , 85 ]. These approaches aim to achieve more favorable LET and RBE distributions, thereby minimizing the biological dose in OAR without compromising target volume coverage.…”
Section: Current Clinical Practice and Outlook For Future Clinical Pr...mentioning
confidence: 99%
See 1 more Smart Citation
“…In addition to the indirect approaches commonly applied in current clinical practice, various LET/RBE-guided plan optimization approaches have been proposed [ 75 , 76 , 77 , 78 , 79 , 80 , 81 , 82 , 83 , 84 , 85 ]. These approaches aim to achieve more favorable LET and RBE distributions, thereby minimizing the biological dose in OAR without compromising target volume coverage.…”
Section: Current Clinical Practice and Outlook For Future Clinical Pr...mentioning
confidence: 99%
“…These approaches aim to achieve more favorable LET and RBE distributions, thereby minimizing the biological dose in OAR without compromising target volume coverage. Several methods have been introduced, including optimizing LET [ 75 , 77 , 79 , 80 ], variable RBE-weighted dose [ 82 ], track-end distributions [ 84 ], and introducing “clean dose” (dose deposited by low-LET protons) and “dirty dose” (dose deposited by high-LET protons), penalizing the latter in OAR [ 83 , 85 ]. Early work by Grassberger et al [ 78 ] has demonstrated that pencil beam scanning provides the opportunity to optimize LET distribution without significantly altering the distribution of physical dose.…”
Section: Current Clinical Practice and Outlook For Future Clinical Pr...mentioning
confidence: 99%