The dissolution of urinary catheter encrustation

Abstract: Objectives To identify the optimum volume of acidic bladder washout solution to dissolve catheter encrustations and to compare the effectiveness of different bladder washout delivery devices. Materials and methods Urinary catheter encrustation was generated in vitro using a model of the catheterized bladder adapted from previous work. An acidic bladder washout solution (Suby G) was applied via the catheter in the model and retained for 15 min. The amount of encrusting material dissolved was measured by colorim… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
12
0

Year Published

2000
2000
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(12 citation statements)
references
References 11 publications
0
12
0
Order By: Relevance
“…1,140,[190][191][192][193][194][195][196][197][198][199] Three studies, however, suggest that an acid washout solution (Suby G) is effective in reducing catheter encrustation. 196,198,200 Evidence from best practice supports the findings in respect of bladder irrigation, instillation and washout and indicates that the introduction of such agents may have local toxic effects and contribute to the development of resistant microorganisms. However, continuous or intermittent bladder irrigation may be indicated during urological surgery or to manage catheter obstruction.…”
Section: Irrigation Instillation and Washout Do Not Prevent Infectionmentioning
confidence: 79%
“…1,140,[190][191][192][193][194][195][196][197][198][199] Three studies, however, suggest that an acid washout solution (Suby G) is effective in reducing catheter encrustation. 196,198,200 Evidence from best practice supports the findings in respect of bladder irrigation, instillation and washout and indicates that the introduction of such agents may have local toxic effects and contribute to the development of resistant microorganisms. However, continuous or intermittent bladder irrigation may be indicated during urological surgery or to manage catheter obstruction.…”
Section: Irrigation Instillation and Washout Do Not Prevent Infectionmentioning
confidence: 79%
“…Encrustation of medical devices implanted within the lower urinary tract is virtually ubiquitous when devices remain in situ for 30 days, although only approximately 23% of urinary stents will become encrusted 2. Any model system developed may ultimately only provide a representation of the encrustation process because high degrees of interpatient variation occur in the degree of encrustation observed 45. However, where urine and a urease‐positive bacterial strain are present, the formation of encrustation is assured 25…”
Section: Resultsmentioning
confidence: 99%
“…2 Any model system developed may ultimately only provide a representation of the encrustation process because high degrees of interpatient variation occur in the degree of encrustation observed. 45 However, where urine and a urease-positive bacterial strain are present, the formation of encrustation is assured. 25 The model system described herein has been demonstrated to produce encrusted deposits similar to those observed in a blockage-prone patient.…”
Section: Resultsmentioning
confidence: 99%
“…• Knowledge of appropriate anatomy and physiology. [16][17][18] Patient preparation 8,9 • Ethical issues.…”
Section: Catheter Selection and Sizementioning
confidence: 99%