2019
DOI: 10.1155/2019/8989241
|View full text |Cite
|
Sign up to set email alerts
|

The Dosimetric Comparisons of CRT, IMRT, ARC, CRT+IMRT, and CRT+ARC of Postoperative Radiotherapy in IIIA-N2 Stage Non-Small-Cell Lung Cancer Patients

Abstract: Currently, studies about PORT in stage IIIA-N2 NSCLC patients in recent years have mostly adopted the conformal radiation therapy (CRT) technique, while other modern techniques such as intensity modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT, hereinafter referred to as ARC), helical tomotherapy (HT), and so forth are also developing quickly. In this paper, we intended to compare the dosimetric characteristics of CRT, IMRT, ARC, CRT+IMRT, and CRT+ARC of PORT in stage IIIA-N2 NSCLC pa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 20 publications
0
5
0
Order By: Relevance
“…Based on the above studies, the parameters of lung V 5 , V 13 , V 20 , V 30 and MLD were selected as the criteria for evaluating the lung dose in the present study. Zhang et al (8) found that the lung V 5 and V 10 values obtained using VMAT were significantly higher compared with those found when using IMRT as the technique. In the present study, lung V 5 was found to be the highest with VMAT, especially for patients with a central tumor type and larger PTV (53.59±10.51 and 55.43±10.8, respectively); however, in peripherally located cancer, this parameter was small (46.06±9.88).…”
Section: P-values Of Mus/treatment Time Comparisons Amentioning
confidence: 94%
See 1 more Smart Citation
“…Based on the above studies, the parameters of lung V 5 , V 13 , V 20 , V 30 and MLD were selected as the criteria for evaluating the lung dose in the present study. Zhang et al (8) found that the lung V 5 and V 10 values obtained using VMAT were significantly higher compared with those found when using IMRT as the technique. In the present study, lung V 5 was found to be the highest with VMAT, especially for patients with a central tumor type and larger PTV (53.59±10.51 and 55.43±10.8, respectively); however, in peripherally located cancer, this parameter was small (46.06±9.88).…”
Section: P-values Of Mus/treatment Time Comparisons Amentioning
confidence: 94%
“…3D conformal radiation therapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) now represent the two most accurate radiotherapy techniques (5,6). Numerous studies have been published that have evaluated the advantages of using IMRT over 3D-CRT, in particular with respect to: i) Improving the homogeneity index (HI) and conformity index (CI) of the PTV; and ii) decreasing the absorbed dose in OARs (7)(8)(9)(10). However, the disadvantages of using IMRT should be borne in mind; its increased treatment time may contribute to uncertainties in the prescribed treatment position, which may result in dose changes in PTV.…”
Section: Introductionmentioning
confidence: 99%
“…A comparison of the dosimetric PORT plans of ten pN2 NSCLC patients using 3D-CRT, IMRT and VMAT was unable to reveal that any technique had absolute dosimetry advantages for all patients [ 75 ]. The selection of the technique should be individualized, balancing target coverage and protection of the organs at risk.…”
Section: Port Toxicitymentioning
confidence: 99%
“…However, it is unclear whether more sophisticated modern techniques, such as IMRT, can further improve the toxicity profile. A comparison of dosimetric plans using 3DCRT, IMRT, and volumetric modulated arc therapy RT in 10 patients administered PORT for pN2 disease failed to single out a technique with absolute dosimetry advantages for all patients (54). Therefore, the selection of technique should be based on each individual case using the best compromise between target coverage (efficacy) and the protection of the organs at risk.…”
Section: Port Toxicitymentioning
confidence: 99%