The Ebex Cryostat and Supporting Electronics

Abstract: We describe the cryostat and supporting electronics for the EBEX experiment. EBEX is a balloon-borne polarimeter designed to measure the B-mode polarization of the cosmic microwave background radiation. The instrument includes a 1.5 meter Gregorian-type telescope and 1432 bolometric transition edge sensor detectors operating at 0.3 K. Electronics for monitoring temperatures and controlling cryostat refrigerators is read out over CANbus. A timing system ensures the data from all subsystems is accurately synchro… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2013
2013
2014
2014

Publication Types

Select...
3
2

Relationship

3
2

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 13 publications
0
7
0
Order By: Relevance
“…The cryogenic performance and housekeeping electronics are discussed in detail elsewhere. 17 The cold optics alignment is verified using coordinate-measuring machine (CMM) measurements of the relative positions of the focal plane and lenses to reference points external to the cryostat, which allows for indexing of the cold optics to the warm optics. Before the engineering flight, CMM measurements verified that the optical alignment of all cold optics components was within 0.127 mm (0.005 in) in translation and 0.1 • in rotation of the nominal positions in the optics model.…”
Section: Overviewmentioning
confidence: 99%
See 1 more Smart Citation
“…The cryogenic performance and housekeeping electronics are discussed in detail elsewhere. 17 The cold optics alignment is verified using coordinate-measuring machine (CMM) measurements of the relative positions of the focal plane and lenses to reference points external to the cryostat, which allows for indexing of the cold optics to the warm optics. Before the engineering flight, CMM measurements verified that the optical alignment of all cold optics components was within 0.127 mm (0.005 in) in translation and 0.1 • in rotation of the nominal positions in the optics model.…”
Section: Overviewmentioning
confidence: 99%
“…4 The performance of the cryogenics and receiver housekeeping during the flight is also available elsewhere. 17…”
Section: Overview Of the North American Engineering Flightmentioning
confidence: 99%
“…The SQUIDs in turn are connected in groups of four to digital frequency-domain multiplexing readout (DfMux) boards. 12 The design of the EBEX instrument is detailed elsewhere, 2,8,13 and the bolometer readout system is described in Hubmayr et al 14 and Aubin et al 15 EBEX completed a 13 hour engineering flight from Ft. Sumner, New Mexico in June 2009. In this paper we describe the software and data flow architecture that make up the EBEX control and monitoring systems.…”
Section: Instrument Descriptionmentioning
confidence: 99%
“…The time servers broadcast synchronization messages onto the CANbus, and distribute timing data to the DfMux boards and ACS via an RS-485 serial link that does not connect to the flight computers. The housekeeping and timing subsystems are described in Sagiv et al 13…”
Section: Systemsmentioning
confidence: 99%
“…We have developed multilayer epoxy-based dielectric AR coatings with more than 90% fractional bandwidth. While multilayer dielectric coatings have been developed [6][7][8], our moldable adhesive coatings have the advantage of being applicable for high dielectric constant curved lenses. Additionally, we can tune the dielectric constant of our layers, which allows for broad application of our coatings.…”