The Effect of Calibration Factors and Recovery Coefficients on 177Lu SPECT Activity Quantification Accuracy: A Monte Carlo Study

Abstract: Background: Different gamma camera calibration factor (CF) geometries have been proposed to convert SPECT data into units of activity concentration. However, no consensus has been reached on a standardized geometry. The CF is dependent on the selected geometry and affected by partial volume effects. This study investigated the effect of two CF geometries and their corresponding recovery coefficients (RCs) on the quantification accuracy of 177Lu SPECT images using Monte Carlo simulations.Methods: The CF geometr… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 54 publications
0
3
0
Order By: Relevance
“…Image reconstruction was performed using the General Electric (GE) Dosimetry toolkit (DTK) software [19] available for the Xeleris 3.0 Workstation (International General Electric, General Electric Medical Systems, Haifa, Israel). The ordered subsets expectation maximization (OSEM) algorithm with a subset and iteration product of 100 (10 iteration and 10 subsets) was used in order to obtain counts convergence in small VOIs [12]. Additionally, attenuation correction (from CT attenuation maps) and resolution recovery (for reducing image blurring) included in the Xeleris 3.0 workstation were used.…”
Section: Image Acquisition and Reconstructionmentioning
confidence: 99%
See 2 more Smart Citations
“…Image reconstruction was performed using the General Electric (GE) Dosimetry toolkit (DTK) software [19] available for the Xeleris 3.0 Workstation (International General Electric, General Electric Medical Systems, Haifa, Israel). The ordered subsets expectation maximization (OSEM) algorithm with a subset and iteration product of 100 (10 iteration and 10 subsets) was used in order to obtain counts convergence in small VOIs [12]. Additionally, attenuation correction (from CT attenuation maps) and resolution recovery (for reducing image blurring) included in the Xeleris 3.0 workstation were used.…”
Section: Image Acquisition and Reconstructionmentioning
confidence: 99%
“…acquisitions. The conventional quantification method [12,21] uses the sphere CFs calculated from NEMA Cal. 1 acquisition and the background CF calculated from PET cylindrical phantom for quantification of the large organs, without taking background effects into consideration.…”
Section: Validation Of Quantitative Imagingmentioning
confidence: 99%
See 1 more Smart Citation