2005
DOI: 10.1563/1548-1336(2005)31[115:teoccl]2.0.co;2
|View full text |Cite
|
Sign up to set email alerts
|

The Effect of Compressive Cyclic Loading on Retention of a Temporary Cement Used with Implants

Abstract: Masticatory forces cause fatigue to cement-retained crowns and abutments and may adversely effect retention. The relation between the number of load cycles and the retentive forces is important. This study evaluated the effect of compressive cyclic loading on the retentive forces of a temporary cement used to retain implant crowns and the relationship between load cycles and retentive forces. Ten castings and implant abutments were cemented with zinc oxide-eugenol temporary cement. The retentive force necessar… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
28
0
4

Year Published

2008
2008
2019
2019

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(33 citation statements)
references
References 13 publications
1
28
0
4
Order By: Relevance
“…; Ongthiemsak et al. ), zinc oxide/eugenol cement (TempBond) is highly soluble in water and requires 4 min to achieve complete cure in order to increase its retention. Dudley et al.…”
Section: Discussionmentioning
confidence: 99%
“…; Ongthiemsak et al. ), zinc oxide/eugenol cement (TempBond) is highly soluble in water and requires 4 min to achieve complete cure in order to increase its retention. Dudley et al.…”
Section: Discussionmentioning
confidence: 99%
“…In this study, 500 000 cycles of loading-each cycle for 0.2 seconds-were used, which is similar to cycle of loading of 6 months' mastication in human adults. 46 However, it should be mentioned that there are limitations to any in vitro study that tries to simulate the biomechanics of chewing, and interpretation of the results should be done with that in mind. 48 The type of implants used in this study was internal hex with platform switching.…”
Section: Discussionmentioning
confidence: 99%
“…The cycle loading was equivalent to 6 months' mastication in human adults. 46,47 A 75 N load was applied perpendicular to occlusal surface of each crown. The contact time between the rod and crown was adjusted to 0.2 seconds with a frequency of 1 Hz, which simulates the tooth contact duration of each masticatory cycle.…”
Section: Secondary Torque Loss After Cyclic Loadingmentioning
confidence: 99%
“…The in vitro compressive cyclic loading is a condition that can be used to simulate occlusal stress present in the oral environment, affecting the retention of provisional luting agents and predicting the in vivo behavior of these materials (12,13).…”
Section: Introductionmentioning
confidence: 99%