2016
DOI: 10.1080/03772063.2016.1176543
|View full text |Cite
|
Sign up to set email alerts
|

The Effect of Duty Cycle and Brightness Variation of Visual Stimuli on SSVEP in Brain Computer Interface Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
11
0
2

Year Published

2016
2016
2022
2022

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 14 publications
(13 citation statements)
references
References 39 publications
0
11
0
2
Order By: Relevance
“…However, recent advances in SSVEP-based BCIs have developed techniques and algorithms to overcome these obstacles. Several studies have proposed different stimulus design techniques to realize large number of targets with only few frequencies, but they have also suffered limitations [21,38,43,50,57,58,90]. Furthermore, a few researchers combined SSVEPs with P300 to generate more targets with less frequencies, but this was at the cost of task complexity, which eventually affected the performance of the system.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, recent advances in SSVEP-based BCIs have developed techniques and algorithms to overcome these obstacles. Several studies have proposed different stimulus design techniques to realize large number of targets with only few frequencies, but they have also suffered limitations [21,38,43,50,57,58,90]. Furthermore, a few researchers combined SSVEPs with P300 to generate more targets with less frequencies, but this was at the cost of task complexity, which eventually affected the performance of the system.…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, it has also been shown that low-frequency stimuli can cause photosensitivity-based epileptic seizures and high-levels of visual fatigue and discomfort, especially when presented with large number of targets and longer periods [21,43]. Many studies have used high-frequency stimuli and variable duty cycles to reduce visual fatigue and discomfort but at the cost of a decrease in the performance of SSVEP-based BCIs [21,43,[56][57][58]. A few authors have also combined other EEG signals, e.g., P300, with SSVEP to overcome these limitations [22,[59][60][61][62][63].…”
mentioning
confidence: 99%
“…measurement. Because EEG has strong signal response, high signal to noise ratio (SNR), and practical usage [6]. Moreover, EEG measurement is a non-invasive method.…”
Section: Introductionmentioning
confidence: 99%
“…Sistemin bütünündeki doğruluk oranı ise; doğru karakter seçimi ADAA algoritmasına göre yüzdesi olarak hesaplanmıştır 4. farklı heceletici modundaki deneyler sounucunda bütün katılımcıların 45 karakterlik test oturumundaki doğruluk oranı, bir dizideki en yüksek doğruluğa sahip tur sayısı ile hesaplanmıştır.…”
unclassified