2003
DOI: 10.1080/18811248.2003.9715438
|View full text |Cite
|
Sign up to set email alerts
|

The Effect of Neutron Source Distribution on Subcriticality Measurement of Pressurized Water Reactors Using the Modified Neutron Source Multiplication Method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2005
2005
2024
2024

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 4 publications
0
6
0
Order By: Relevance
“…4,5) The neutron count rate is adjusted to be used as an input signal to a digital reactivity meter by the three correction factors introduced in the modified NSM method. These factors are extraction correction factor, spatial correction factor and importance field correction factor; The extraction correction factor is related to the extraction of the fundamental mode, spatial correction factor corrects a spatial effect induced by the disturbance of the fundamental mode and importance field correction factor corrects the effect induced by the disturbance of neutron importance field.…”
Section: Correction Factors Of the Modified Nsm Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…4,5) The neutron count rate is adjusted to be used as an input signal to a digital reactivity meter by the three correction factors introduced in the modified NSM method. These factors are extraction correction factor, spatial correction factor and importance field correction factor; The extraction correction factor is related to the extraction of the fundamental mode, spatial correction factor corrects a spatial effect induced by the disturbance of the fundamental mode and importance field correction factor corrects the effect induced by the disturbance of neutron importance field.…”
Section: Correction Factors Of the Modified Nsm Methodsmentioning
confidence: 99%
“…Figure 2 reviews a withdrawal sequence of control rod banks during the critical approach used in a two-loop type commercial PWR as described in the previous studies. 4,5) As can be seen in this figure, five temporal rest states were selected for subcriticality calculation. Each control rod bank was withdrawn from 0 step to 228 steps with equal space between All-Rod-In (ARI) and All-Rod-Out (ARO).…”
Section: Correction Factors Of the Modified Nsm Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The count rates corresponding to various control rod configurations were calculated using neutron flux distributions obtained with fixed source problems and the detector response as explained in Ref. 5). The simulated result is shown in Fig.…”
Section: Prediction Of the Expected Response Of Neutronmentioning
confidence: 99%
“…6). The subcriticality for each control rod pattern was calculated by solving the eigenvalue problem.…”
Section: Numerical Simulationmentioning