The Effect of Operative Field Instrument Clutter During Intraoperative Fluoroscopy on Radiation Exposure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1
1

Relationship

2
5

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 22 publications
0
6
0
Order By: Relevance
“…This is likely due to the effect of introducing hyperdense objects, such as radiation-attenuating gloves, into the path of the uoroscopy beam. This has been shown to increase the radiation produced by the machine when it is operating in the AEC setting [14]. On the other hand, the needle holder is made from a low-density material and has a slim contour, which may have allowed the uoroscopy machine to generate a lower radiation dose.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…This is likely due to the effect of introducing hyperdense objects, such as radiation-attenuating gloves, into the path of the uoroscopy beam. This has been shown to increase the radiation produced by the machine when it is operating in the AEC setting [14]. On the other hand, the needle holder is made from a low-density material and has a slim contour, which may have allowed the uoroscopy machine to generate a lower radiation dose.…”
Section: Discussionmentioning
confidence: 99%
“…Fluoroscopy was performed using a GE OEC 9900 portable C-arm system (GE Medical system, Inc., Salt Lake City, UT) using the default automatic exposure control (AEC) for all trials. The AEC adjusts the milliampere-seconds (mAs) and peak kilovoltage (kVp) based on the target density to provide optimal image quality [14]. The C-arm was positioned over the right kidney with the X-ray source below the table and the image intensi er above the patient at a skin-to-source distance of 20 cm.…”
Section: Radiation Dose Measurementsmentioning
confidence: 99%
“…Fluoroscopy was performed using a GE OEC 9900 portable C-arm system (GE Medical system, Inc., Salt Lake City, UT) using the default automatic exposure control (AEC) for all trials. The AEC adjusts the milliampere-seconds (mAs) and peak kilovoltage (kVp) based on the target density to provide optimal image quality [ 14 ]. The C-arm was positioned over the right kidney with the X-ray source below the table and the image intensifier above the patient at a skin-to-source distance of 20 cm.…”
Section: Methodsmentioning
confidence: 99%
“…56,57 Modern fluoroscopy systems help to reduce radiation dose by automatic adjustment of dosage (automatic brightness control; ABC) and there are functions to save the last image. 58 When ABC is being used, one should avoid putting radio-opaque objects inside the beam as this will cause an automatic increase in radiation dose. One study demonstrated that when radio-opaque objects including lateral operating table support, endoscopy cameras, light cords and flexible ureteroscopy is placed inside the field, the C-arm radiation dose increases by 35%.…”
Section: X-ray Positioning and Modesmentioning
confidence: 99%
“…One study demonstrated that when radio-opaque objects including lateral operating table support, endoscopy cameras, light cords and flexible ureteroscopy is placed inside the field, the C-arm radiation dose increases by 35%. 58 The physicians and assistants should pay attention to clear clutters of instruments and objects on the operating table. Fluoroscopy settings also help reduce the radiation hazard.…”
Section: X-ray Positioning and Modesmentioning
confidence: 99%