2012
DOI: 10.1007/s11999-011-2052-2
|View full text |Cite
|
Sign up to set email alerts
|

The Effect of Poly Sterilization on Wear, Osteolysis and Survivorship of a Press-fit Cup at 10-Year Followup

Abstract: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
13
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 15 publications
(13 citation statements)
references
References 40 publications
0
13
0
Order By: Relevance
“…Moreover, various factors such as the material shape and geometry, surface finish, and bearing surface affect the durability of a component, and the surgical approach used and the expertise of the surgeon may also affect its survivorship 18 . Other important factors that can influence the in vivo wear properties of the bearing surface are the shelf life and sterilization environment (air or an inert environment) of the polyethylene 19,20 . Regardless of these factors, the method of fixation of the acetabular component also affects survivorship of this component.…”
mentioning
confidence: 99%
“…Moreover, various factors such as the material shape and geometry, surface finish, and bearing surface affect the durability of a component, and the surgical approach used and the expertise of the surgeon may also affect its survivorship 18 . Other important factors that can influence the in vivo wear properties of the bearing surface are the shelf life and sterilization environment (air or an inert environment) of the polyethylene 19,20 . Regardless of these factors, the method of fixation of the acetabular component also affects survivorship of this component.…”
mentioning
confidence: 99%
“…Calvert, et al reported more than 100% volumetric wear reduction of HXLP vs. conventional polyethylene in a randomized prospective study [3]. Long-term data reported by Engh et al showed the wear rate of conventional polyethylene to be 0.23 mm 3 /year as opposed to 0.04 mm 3 /year in HXLP [7]. The mechanical strength of a third-generation highly crosslinked polyethylene (X 3 , Stryker Orthopaedics, Mahwah, NJ) as measured by yield and ultimate fatigue has also been reported to be not significantly different from conventional polyethylene [6].…”
Section: Resultsmentioning
confidence: 98%
“…The 5 different cups evaluated included different radii, porous-coating, macrotextured surfaces and peripheral fins designs and we could not detect a better intraoperative fixation for any 1 design (8, 26). To date, although porous-coated ingrowth cups are widely used, different uncemented fixation types consistently provide excellent results in terms of bone fixation (2729).…”
Section: Discussionmentioning
confidence: 99%