2020
DOI: 10.3390/en13081946
|View full text |Cite
|
Sign up to set email alerts
|

The Effect of the NaCl Bulk Concentration on the Resistance of Ion Exchange Membranes—Measuring and Modeling

Abstract: Ion exchange membranes are used in different fields of energy and separation technology such as electrodialysis, reverse electrodialysis, and fuel cells. Important aspects are permselectivity, resistance, and water transport. In this paper, we focus on the effect of the bulk NaCl concentration on the membrane resistance. Data from 36 publications containing 145 datasets using 6 different methods for measuring membrane resistance were compared. This study showed that the membrane resistance is dependent on the … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0
5

Year Published

2020
2020
2023
2023

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 24 publications
(27 citation statements)
references
References 58 publications
0
21
0
5
Order By: Relevance
“…By contrast, the conductivity value reported by the manufacturer is 3 to 8 mS·cm −1 (0.5 M NaCl at 25 °C, through-plane measuring cell), higher than that found in this study. The method of measuring and the presence of free salt could be the main reason for the variation in the membrane conductivity [ 56 ].…”
Section: Resultsmentioning
confidence: 99%
“…By contrast, the conductivity value reported by the manufacturer is 3 to 8 mS·cm −1 (0.5 M NaCl at 25 °C, through-plane measuring cell), higher than that found in this study. The method of measuring and the presence of free salt could be the main reason for the variation in the membrane conductivity [ 56 ].…”
Section: Resultsmentioning
confidence: 99%
“…Regarding MK-40 and MA-41 membranes, a large scatter of their conductivity is also found in the literature, and Veerman gives a good collection of data in [39]. As in the case of Ralex membranes, different production conditions seem to be the leading cause of such a wide range of electrical conductivity.…”
Section: Conductivity Measurement Resultsmentioning
confidence: 72%
“…This behaviour was associated with the IEM morphology by following the micro-heterogeneous model [75,76], which represents the membrane with multi-phase structure [77], also containing the solution from outside. There are various physical models, and also phenomenological models for membrane resistance [78]. Moreover, a diverse behaviour was found by some measurements [74], thus this topic could deserve further investigation.…”
Section: Ion Exchange Membranes and Mass Transfermentioning
confidence: 99%