2013
DOI: 10.4187/respcare.02339
|View full text |Cite
|
Sign up to set email alerts
|

The Effects of Abnormal Blood Pressure on Arterial Sampler Filling Times

Abstract: BACKGROUND: Sampler filling time begins with the initial flash of blood in the needle hub until the preset sampler volume is obtained. Previous studies have shown statistically significant differences between arterial and venous sampler filling times, but included only a few subjects with abnormal blood pressures. OBJECTIVE: To determine whether the time required to fill a vented arterial sampler is an accurate indication of a successful arterial blood sample in adults with abnormal blood pressure. We hypothes… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
1
0

Year Published

2014
2014
2014
2014

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 8 publications
1
1
0
Order By: Relevance
“…Our study further supports previous studies conducted by Johnson et al, 1 Bender et al, 2 and Cortes et al, 3 who concluded that arterial sampler filling time can distinguish between arterial and venous punctures. Johnson et al 1 used an extracorporeal laboratory model and tested various needle sizes, whereas Bender et al 2 studied subjects with normal mean arterial pressures, and Cortes et al 3 studied subjects with abnormal blood pressures.…”
Section: Discussionsupporting
confidence: 93%
See 1 more Smart Citation
“…Our study further supports previous studies conducted by Johnson et al, 1 Bender et al, 2 and Cortes et al, 3 who concluded that arterial sampler filling time can distinguish between arterial and venous punctures. Johnson et al 1 used an extracorporeal laboratory model and tested various needle sizes, whereas Bender et al 2 studied subjects with normal mean arterial pressures, and Cortes et al 3 studied subjects with abnormal blood pressures.…”
Section: Discussionsupporting
confidence: 93%
“…Bender et al 2 studied sampler filling times in human subjects with normal mean arterial pressures and concluded that arterial puncture filling time is significantly faster than venopuncture. Cortes et al 3 showed that there was no statistically significant difference in arterial filling times for subjects with abnormal blood pressures. Although these studies showed that sampler filling time is a useful indicator that the sample is arterial, all 3 studies used only the Portex Pro-Vent arterial sampler (Smiths Medical, Dublin, Ohio) in their comparisons.…”
Section: Introductionmentioning
confidence: 98%