1980
DOI: 10.1001/archotol.1980.00790360012004
|View full text |Cite
|
Sign up to set email alerts
|

The Effects of an Adhesive in the Middle Ear

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
8
1
1

Year Published

1987
1987
2011
2011

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(10 citation statements)
references
References 4 publications
0
8
1
1
Order By: Relevance
“…The clot constituted by the fibrin glue is a physiologic component found in tissue repair, and this makes it different from other types of glue such as the cyanoacrylates, which bear high fibrin formation, and is very difficult to use in moist tissue, induce fibrosis, foreign body reaction, and significant inflammatory response 15, 16. Moreover, the polymerization of this family of tissue glue is exothermic and it should be avoided in areas that may be liable to heat damage.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The clot constituted by the fibrin glue is a physiologic component found in tissue repair, and this makes it different from other types of glue such as the cyanoacrylates, which bear high fibrin formation, and is very difficult to use in moist tissue, induce fibrosis, foreign body reaction, and significant inflammatory response 15, 16. Moreover, the polymerization of this family of tissue glue is exothermic and it should be avoided in areas that may be liable to heat damage.…”
Section: Discussionmentioning
confidence: 99%
“…Moreover, the polymerization of this family of tissue glue is exothermic and it should be avoided in areas that may be liable to heat damage. Thus, they are not recommended for middle ear surgery 15, 16…”
Section: Discussionmentioning
confidence: 99%
“…1 More recent compounds have been shown to be neither ototoxic 2 nor to cause signi cant in ammatory response, 3 although some controversy surrounds these assertions as contemporary studies 4 have demonstrated signi cant tissue reaction. It may be that the differences between these and other studies can be explained by the different species of animal utilized.…”
Section: Discussionmentioning
confidence: 99%
“…For our purposes, however, this was not adequate specifically regarding the interface [16]. Studies have shown that the use of histoacryl or similar substances can lead to extensive biological reactions which could endanger the implanted devices [17,18].…”
Section: Discussionmentioning
confidence: 99%