Proceedings ISDEIV. 18th International Symposium on Discharges and Electrical Insulation in Vacuum (Cat. No.98CH36073)
DOI: 10.1109/deiv.1998.738860
|View full text |Cite
|
Sign up to set email alerts
|

The effects of electrode cleaning and conditioning on the performance of high-energy, pulsed-power devices

Abstract: -High-energy pulsed-power devices routinely access field strengths above those at which broad-area, cathode-initiated, high-voltage vacuum-breakdown occur (> le7 -3e7 V/m). Examples include magnetically-insulatedtransmission-lines and current convolutes, high-currentdensity electron and ion diodes, high-power microwave devices, and cavities and other structures for electrostatic and RF accelerators. Energy deposited in anode surfaces may exceed anode plasma thermal-desorption creation thresholds on the time-sc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 52 publications
0
1
0
Order By: Relevance
“…Gas multiplicative mechanism cannot act either, because electron mean free path is much larger than the interelectrode gap. The increase of the avalanche mechanism contribution to breakdown initiation with the rise of pressure can be attributed to the fact that high pressure enlarges the adsorbed gas layer on the electrodes, which leads to a higher probability of avalanche charge exchange between the electrodes, and consequently of breakdown [12][13][14]. Figure 11 shows the dependence of vacuum diode breakdown voltage mean, maximum and minimum values on the inter-electrode gap width at p = 10 -4 Pa (10 -9 bar) (types 1, 2 and 3 vacuum diodes).…”
Section: The Experimentsmentioning
confidence: 99%
“…Gas multiplicative mechanism cannot act either, because electron mean free path is much larger than the interelectrode gap. The increase of the avalanche mechanism contribution to breakdown initiation with the rise of pressure can be attributed to the fact that high pressure enlarges the adsorbed gas layer on the electrodes, which leads to a higher probability of avalanche charge exchange between the electrodes, and consequently of breakdown [12][13][14]. Figure 11 shows the dependence of vacuum diode breakdown voltage mean, maximum and minimum values on the inter-electrode gap width at p = 10 -4 Pa (10 -9 bar) (types 1, 2 and 3 vacuum diodes).…”
Section: The Experimentsmentioning
confidence: 99%