The effects of metals on a transcutaneous energy transmission system

Abstract: The effects of metal objects on the mutual inductance, self-inductance, and effective series resistance (ESR) of the coaxial coils of a transcutaneous energy transmission system (TETS) were investigated theoretically and experimentally. The theory considers a thin conducting sheet of infinite size aligned parallel to a current-carrying coil. Results of the theory indicate that coil parameters vary with the distance from the sheet to the coil. Changes in mutual and self inductance are independent of the conduct… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

1998
1998
2019
2019

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 25 publications
(7 citation statements)
references
References 2 publications
0
7
0
Order By: Relevance
“…Although technically achievable, the sheer complexity of this system not only raised the risk of device failure but also significantly increased system cost. Another less obvious worry stemmed from the fact that metal objects placed in the vicinity of the coils were found to detune the circuit by altering their mutual inductance and effective series resistance (24,25). This power scheme therefore requires a rigid metallic enclosure (offset several inches from the external coil) to shield the transformer coils against environmental interference that could lead to system failure.…”
Section: Discussionmentioning
confidence: 99%
“…Although technically achievable, the sheer complexity of this system not only raised the risk of device failure but also significantly increased system cost. Another less obvious worry stemmed from the fact that metal objects placed in the vicinity of the coils were found to detune the circuit by altering their mutual inductance and effective series resistance (24,25). This power scheme therefore requires a rigid metallic enclosure (offset several inches from the external coil) to shield the transformer coils against environmental interference that could lead to system failure.…”
Section: Discussionmentioning
confidence: 99%
“…Although technically achievable, the sheer complexity of this system not only raised the risk of device failure but also significantly increased system cost. Another less obvious worry stemmed from the fact that metal objects placed in the vicinity of the coils were found to detune the circuit by altering their mutual inductance and effective series resistance (24,25). This power scheme therefore requires a rigid metallic enclosure (offset several inches from the external coil) to shield the transformer coils against environmental interference that could lead to system failure.…”
Section: Discussionmentioning
confidence: 99%
“…Another heating mechanism is eddy and circular current heating. When magnetic fields pass through conductive material (packaging) such as titanium alloy, eddy and circular currents are generated, which results in increased heat because of I 2 R losses in the conductor (Geselowitz et al, 1992). The last mechanism for heat increase is a result of the direct absorption of electromagnetic energy by tissue called electromagnetic heating.…”
Section: Implant Heatingmentioning
confidence: 99%